Product details:
DUT power setting:
The PA has 7 levels from the lowest power to highest (PA7). Our products use the 2
nd
level (PA6 ) .
Caution:
The test program is default that DUT emits max. power ( highest level ) but all our FW setting only
use 2
nd
level.
Please keep in mind that make sure to lower the power during every single test.
Test procedures:
test program : WUSBLP_Test.exe
after execute it you will see the panel below :
How to use :
1. CW:
1) press " CH Center Freq." button to enter CW mode;
then press " 2402 MHz" or "2441 MHz" or " 2481 MHz"
to choose lowest, middle and highest frequencies;
for other frequencies, please press “channel –“ or “c” to select channel.
2)
press “ PA Bias – “ once to select output power
PS: don’t press more than once otherwise the power won’t be correct.
The proper way to make sure that the power setting is right:
Press “ PA Bias + “ first to let it max. power and then press “ PA Bias – “ to enter the correct
setting