If the disk has failed, a fault LED is lit on the front panel of the affected drawer. The illuminated LED will either be the Drawer LED
or the Logical LED.
•
If the disk has failed, the Drive Fault LED on the DDIC cover is lit amber.
2
Open the relevant drawer.
3
Locate the DDIC to be replaced using any of the methods listed in step 1 above.
4
On the face of the DDIC, push the latch button in the direction shown in
to unlock the DDIC from its seated position
in the slot.
Figure 51. Removing a DDIC (1 of 2)
5
Pull the DDIC upwards and out of the drawer slot.
Figure 52. Removing a DDIC (2 of 2)
62
Module removal and replacement