Appendix A. Additional specifications
Topics:
•
•
•
•
•
PSU specifications
The PowerEdge R740 system supports up to two AC or DC power supply units (PSUs).
Table 23. PSU specifications
PSU
Class
Heat dissipation
(maximum)
Frequency
Voltage
Current
495 W AC
Platinum
1908 BTU/hr
50/60 Hz
100–240 V AC, autoranging
6.5 A–3 A
750 W AC
Platinum
2891 BTU/hr
50/60 Hz
100–240 V AC, autoranging
10 A–5 A
750 W AC
Titanium
2843 BTU/hr
50/60 Hz
200–240 V AC, autoranging
5 A
750 W Mixed
Mode HVDC (for
China only)
Platinum
2891 BTU/hr
50/60 Hz
100–240 V AC, autoranging
10 A–5 A
N/A
2891 BTU/hr
N/A
240 V DC, autoranging
4.5 A
1100 W AC
Platinum
4100 BTU/hr
50/60 Hz
100–240 V AC, autoranging
12 A–6.5 A
1100 W DC
N/A
4416 BTU/hr
N/A
–(48–60) V DC, autoranging
32 A
1100 W Mixed
Mode HVDC (for
China and Japan
only)
Platinum
4100 BTU/hr
50/60 Hz
100–240 V AC, autoranging
12 A–6.5 A
N/A
4100 BTU/hr
N/A
200–380 V DC, autoranging
6.4 A–3.2 A
1600 W AC
Platinum
6000 BTU/hr
50/60 Hz
100–240 V AC, autoranging
10 A
2000 W AC
Platinum
7500 BTU/hr
50/60 Hz
100–240 V AC, autoranging
11.5 A
NOTE:
Heat dissipation is calculated using the PSU wattage rating.
NOTE:
This system is also designed to connect to the IT power systems with a phase to phase voltage not exceeding 240 V.
NOTE:
If a system with 2000 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 1000 W.
NOTE:
If a system with 1600 W AC PSU operates at low line 100–120 V AC, then the power rating per PSU is derated to 800 W.
NOTE:
If system with 1100 W AC PSU or 1100 W Mixed Mode HVDC PSU operates at low line 100–120 V AC, then the power
rating per PSU is derated to 1050 W.
11
Appendix A. Additional specifications
71