5
Select ports Ethernet 1/1/1-Ethernet 1/1/8 and the uplink port channel.
6
Click
Configure MTU
and set MTU to 9216.
7
Click
Finish
.
Jumbo frames that are required for the Cloud Foundation are configured.
Server templates
A server template contains the parameters that are extracted from a server and allows the parameters to be quickly applied to multiple
compute sleds. First, create an empty template by copying one from any existing compute sled. Then, modify the template and then apply
it to new compute sleds as needed.
Create a server template
About this task
To create a server template, perform the following steps:
Steps
1
Open the
OME-M
console.
2
From the
Configuration
menu, click
Deploy
.
3
In the center pane, click
Create Template
, and then click
From Reference Device
.
4
In the
Create Template
window, complete the following steps:
a In the
Template Name
box, enter MX740c with Intel mezzanine.
b Optionally, enter the description in the
Description
box.
c Click
Next
.
d In the
Device Selection
pane, click
Select Device
.
e In the
Select Devices
window, select
Sled-1 from Chassis-1
, and then click
Finish
.
f
From the
Elements to Clone
list, select the following options:
1
iDRAC
2
System
3
NIC
g Click
Finish
.
A job starts and the new server template is displayed on the list. When the job completes, the status is displayed as
Completed
Successfully
.
Next step
After the job completes, associate the VLANs created earlier with the template.
Associate server template with a VLAN
Prerequisite
Before the server template is associated with VLAN, a server template must be created. For more information on creating the server
template, see
.
About this task
To associate the server template with VLAN, perform the following steps:
Steps
1
In the
Deploy
pane, select the
MX740c with Intel mezzanine
server template, and then click
Edit Network
.
2
In the
Edit Network
window, perform the following steps:
a Optionally, from the
Identity Pool
list, select
Ethernet ID Pool
.
b From the
Untagged Network
list, select the VLAN previously created to be the untagged VLAN for both ports.
c From the
Tagged Network
list, select all of the tagged VLANs for both ports.
60
SmartFabric network configuration
Summary of Contents for PowerEdge MX7000
Page 1: ...Dell EMC VMware Cloud Foundation for PowerEdge MX7000 Deployment Guide ...
Page 8: ...Figure 1 Cloud Foundation deployment workflow 8 Overview ...
Page 27: ...Figure 19 Dual PowerEdge MX7000 enclosure configuration Physical layout 27 ...
Page 29: ...Figure 20 MX9002m Management module cabling Physical layout 29 ...
Page 30: ...Figure 21 Connectivity between FSE modules and FEM modules 30 Physical layout ...
Page 31: ...Figure 22 Uplinks to customer network environment Physical layout 31 ...
Page 42: ...Figure 25 MX9002m Management Module cabling 42 Networking requirements ...
Page 43: ...Figure 26 Connectivity between FSE modules and FEM modules Networking requirements 43 ...
Page 44: ...Figure 27 Uplinks to customer network environment 44 Networking requirements ...