Specifications

Remote Refrigerated Work Tables

Model

# Of Doors

Shelf Max 

Load (lbs)

Base Volume 

FT3

Shelf 

Area FT2

Volts/Hertz/

Phase

Amps

BTU Load

EVAP. BTU/°TD

F18WR31

(1) 19”

70

7.56

2.56

115/60/1

3.0

383

120/3°

F18WR39

(1) 27”

124

10.23

3.95

115/60/1

3.0

465

120/4°

F18WR44

(2) 19”

70

12.14

5.12

115/60/1

3.0

605

120/5°

F18WR52

(1) 19” & (1) 27”

70/124

15.12

6.51

115/60/1

3.0

686

120/6°

F18WR60

(2) 27”

124

18.10

7.90

115/60/1

3.0

768

120/6°

F18WR70

(2) 32”

140

21.23

9.64

115/60/1

3.0

869

120/7°

F18WR79

(2) 27” & (1) 19”

124/70

24.48

10.29

115/60/1

6.0

1050

240/4°

F18WR87

(3) 27”

124

27.46

11.85

115/60/1

6.0

1131

240/5°

Self-Contained Refrigerated Work Tables

Model

# Of Doors

Shelf Max 

Load (lbs)

Base Volume 

FT3

Shelf 

Area FT2

Volts/Hertz/

Phase

Amps

BTU Load BTU System Cap.

R-404A 

oz.

H.P.

NEMA 

Plug

F18WC39

(1) 19”

70

7.56

2.56

115/60/1

8.0

383

1462

16

1/5

5-15P

F18WC47

(1) 27”

124

10.23

3.95

115/60/1

8.0

465

1462

16

1/5

5-15P

F18WC52

(2) 19”

70

12.14

5.12

115/60/1

8.0

605

1462

16

1/5

5-15P

F18WC60

(1) 19” & (1) 27”

70/124

15.12

6.51

115/60/1

8.0

686

1462

16

1/5

5-15P

F18WC68

(2) 27”

124

18.10

7.90

115/60/1

10.0

768

1462

16

1/4

5-15P

F18WC78

(2) 32”

140

21.23

9.64

115/60/1

10.0

869

1994

16

1/4

5-15P

F18WC87

(2) 27” & (1) 19”

124/70

24.48

10.29

115/60/1

10.0

1050

2261

16

1/4

5-15P

F18WC95

(3) 27”

124

27.46

11.85

115/60/1

10.0

1131

2261

16

1/4

5-15P

Remote Refrigerated Mega Top Salad Tables

Model

# Of Doors

Shelf Max 

Load (lbs)

Base Volume 

FT3

# of Pans

Volts/Hertz/

Phase

Amps

BTU Load  

Base/Rail

EVAP. BTU/°TD 

Base/Rail

F18MR31A

(1) 19”

70

4.14

6

115/60/1

3.0

280/265

120/2°/12/22°

F18MR44A

(2) 19”

70

7.15

6

115/60/1

3.0

444/265

120/4°/12/22°

F18MR44D

(2) 19”

70

7.15

12

115/60/1

3.0

444/529

120/4°/22/25°

F18MR52A

(1) 19” & (1) 27”

70/124

8.97

6

115/60/1

3.0

515/265

120/4°/12/22°

F18MR52D

(1) 19” & (1) 27”

70/124

8.97

12

115/60/1

3.0

515/529

120/4°/22/25°

F18MR52E

(1) 19” & (1) 27”

70/124

8.97

18

115/60/1

3.0

515/794

120/4°/31/26°

Self-Contained Refrigerated Mega Top Salad Tables

Model

# Of Doors

Shelf Max 

Load (lbs)

Base Volume 

FT3

# of Pans

Volts/Hertz/

Phase

Amps

BTU Load 

Base/Rail

BTU System Cap. 

Base/Rail

R-404A 

oz.

H.P.

NEMA 

Plug

F18MC39A

(1) 19”

70

4.14

6

115/60/1

10.0

280/265

1903/925

16

1/4

5-15P

F18MC39D

(1) 19”

70

4.14

12

115/60/1

10.0

280/529

1903/1156

16

1/4

5-15P

F18MC52A

(2) 19”

70

7.15

6

115/60/1

10.0

444/265

1903/925

16

1/4

5-15P

F18MC52D

(2) 19”

70

7.15

12

115/60/1

10.0

444/529

1903/1156

16

1/4

5-15P

F18MC52E

(2) 19”

70

7.15

18

115/60/1

10.0

444/794

1903/1321

16

1/4

5-15P

F18MC60A

(1) 19” & (1) 27”

70/124

8.97

6

115/60/1

10.0

515/265

2314/864

16

1/4

5-15P

F18MC60D

(1) 19” & (1) 27”

70/124

8.97

12

115/60/1

10.0

515/529

2314/1141

16

1/4

5-15P

F18MC60E

(1) 19” & (1) 27”

70/124

8.97

18

115/60/1

10.0

515/794

2314/1361

16

1/4

5-15P

F18MC60F

(1) 19” & (1) 27”

70/124

8.97

24

115/60/1

10.0

515/1058

2314/1540

16

1/4

5-15P

Summary of Contents for F18MC39A

Page 1: ...ated Work Tables Salad Tables Freezer Bases Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately Important Information Read Before Use Please Save These Instructions ...

Page 2: ... Intended For Use By Persons Who Lack Experience Or Knowledge Unless They Have Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their Safety WARNING This Appliance Is Not To Be Played With Warning Do Not Clean With Water Jet WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance CAUTION Observe the following M...

Page 3: ...Check the lower portion of the unit to be sure legs or casters are not bent 6 Also open the compressor compartment housing and visually inspect the refrigeration package Be sure lines are secure and base is still intact 7 Freight carriers can supply the necessary forms upon request 8 Retain all crating material until an inspection has been made or waived Uncrating the Equipment First cut and remov...

Page 4: ...g is located on the inside back of the unit Always have the serial number of your unit available when calling for parts or service A complete list of authorized Delfield parts depots is available at www delfield com 2013 The Delfield Company All rights reserved Reproduction without written permission is prohibited Delfield is a registered trademark of The Delfield Company Serial Number Location Re...

Page 5: ... 10 29 115 60 1 10 0 1050 2261 16 1 4 5 15P F18WC95 3 27 124 27 46 11 85 115 60 1 10 0 1131 2261 16 1 4 5 15P Remote Refrigerated Mega Top Salad Tables Model Of Doors Shelf Max Load lbs Base Volume FT3 of Pans Volts Hertz Phase Amps BTU Load Base Rail EVAP BTU TD Base Rail F18MR31A 1 19 70 4 14 6 115 60 1 3 0 280 265 120 2 12 22 F18MR44A 2 19 70 7 15 6 115 60 1 3 0 444 265 120 4 12 22 F18MR44D 2 1...

Page 6: ...061 16 1 4 5 15P F18SC60A 1 19 1 27 70 124 8 97 6 115 60 1 10 0 515 265 2314 667 16 1 4 5 15P F18SC60B 1 19 1 27 70 124 8 97 8 115 60 1 10 0 515 353 2314 798 16 1 4 5 15P F18SC60C 1 19 1 27 70 124 8 97 10 115 60 1 10 0 515 441 2314 916 16 1 4 5 15P F18SC60D 1 19 1 27 70 124 8 97 12 115 60 1 10 0 515 529 2314 1023 16 1 4 5 15P Remote Refrigerated Reduced Height Rail Model Of Doors Shelf Max Load lb...

Page 7: ... 1 2 5 20P F18RC91 1 19 2 27 70 124 18 68 10 29 115 60 1 14 0 962 1058 3807 1839 22 32 1 2 5 20P F18RC99 3 27 124 21 30 11 85 115 60 1 14 0 1032 1147 3807 1839 24 32 1 2 5 20P Remote Freezer Base Model Of Doors Shelf Max Load lbs Base Volume FT3 Shelf Area FT2 Volts Hertz Phase Amps BTU Load Base Rail Evap BTU TD F18FR35 1 19 70 5 58 2 56 115 60 1 10 0 943 160 6 F18FR50 2 19 70 12 21 5 12 115 60 1...

Page 8: ...dardwithacondensateevaporator If for some reason a unit does not have a condensate evaporator or if the evaporator fails the unit s drain must have an outlet to an appropriate drainage area or container A refrigerated rail will have a 1 2 54cm drain which will need to be run to an appropriate floor drain or container The drain will be stubbed to the bottom of the machine compartment Either run dra...

Page 9: ... lines on wrapped rail units A refrigeration leak in a rail is extremely difficult and costly to repair In some cases it cannot be repaired at all Refrigerator Evaporator Fan Operation When the refrigerator is initially powered up or immediately following a power outage the unit will begin cooling after a 3 6 minutedelay Duringnormaloperationtheevaporatorfanpulses independently of the compressor a...

Page 10: ...ntact the service department at Delfield 800 733 8829 or your local service agent Delfield is not responsible for charges incurred while having the pressure control adjusted Pressure Control Settings Temperature Control Settings A thermostat controls temperature in the self contained F18WC F18FC F18MC base F18SC base F18RC base F18DC base F18PD base and F18PD rails Thermostats are located in the m...

Page 11: ...n pushed towards the back Lift up and slide the drawer track all the way into the drawer cage The blue safety clip will lock in place automatically Once all tracks are replaced insert the drawer box Rest the drawer box bottom track on the front track roller Then push the drawer back in place SLOWLY When the drawer box is about half way in you will hit a STOP You must lift the front of the drawer u...

Page 12: ... in damage to the interior of the cabinet or to the blower coil Overloading the storage area restricting the airflow and continuous opening and closing of the doors and drawers will hamper the units ability to maintain operational temperature Refrigerated rail units Product in the rail should be removed to the refrigerated base at the end of the day This allows you to turn the rail off at night to...

Page 13: ...F18 Series Service and Installation Manual 13 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com Wiring Diagram F18WC Wiring Diagram F18WR ...

Page 14: ...Series Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 14 Wiring Diagram F18MC F18SC F18DC F18RC Wiring Diagram F18MR F18SR F18DR F18RR ...

Page 15: ...F18 Series Service and Installation Manual 15 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com Wiring Diagram F18FR Wiring Diagram F18FC ...

Page 16: ...F18 Series Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 16 Wiring Diagram F18PD ...

Page 17: ...374 Hinge pin for pan cover 0160179 Hinge Kit left or right hinged 3234645 Leg 6 s s 3977984 Shelf 19 door 3977998 Shelf 24 door 3978014 Shelf 27 door 3977983 Shelf 32 door 3234290 Shelf support 1 blue 9321040 Shelf support screw coil side 9321132 Shelf support screw wall side 2190154 Switch rocker 2194201 Thermostat rail 3516225 Valve expansion rail 3516102 Valve solenoid rail F18FC 000 BN5 0053 ...

Page 18: ...e kit lo profile left or right 3234645 Leg 6 s s 9321041 Nut acorn for pan cover 2190154 Switch rocker 2194201 Thermostat rail 3516225 Valve expansion rail 3516102 Valve solenoid rail F18PD48 000 248 0037 Coil assembly R404A Fan Lt 000 BN5 0040 Condensing Assembly 1 3 1 5 Stacked 2194824 Control Danfoss GDM 115V 2194938 Control Tstat Danfoss Etc1h 1 000 402 0056 Cover Assembly hinged 6 pan l t 000...

Page 19: ...30 Coil assembly R404A 000 248 0037 Coil assembly R404A Fan Lt 2194824 Control Danfoss GDM 115V 3234392 Hinge pan cover center 3234282 Hinge pan cover left 3234266 Hinge pan cover right 9321374 Hinge pin for pan cover 0160179 Hinge Kit 3234645 Leg 6 s s 3977984 Shelf 19 door 3977998 Shelf 24 door 3978014 Shelf 27 door 3977983 Shelf 32 door 3234290 Shelf support 1 blue 9321040 Shelf support screw c...

Page 20: ...00 248 0030 Coil assembly R404A 000 248 0037 Coil assembly R404A Fan Lt 000 BN5 0030 Condensing unit 1 4hp R404a 000 BN5 0031 Condensing unit 1 5hp R404a 2194810 Control Danfoss GDM 115V 0160179 Hinge Kit 3234645 Leg 6 s s 3977984 Shelf 19 door 3977998 Shelf 24 door 3978014 Shelf 27 door 3977983 Shelf 32 door 2190154 Switch rocker 3234290 Shelf support 1 blue 9321040 Shelf support screw coil side ...

Page 21: ... 234 0003 Front coil 2184317 Harness coil 2194808 Probe Defrost Danfoss Control 2194809 Probe Temp Sensor Danfoss 1 2 3 4 5 6 7 8 Key Part Number Description 000 249 0006 Coil Assembly Freezer Evap Remote 1 030 262 0001 Side evaporator 2 2160023 Fan axiel 3 2160024 Guard fan 4 7 SC120 W2 4 030 260 0001 Top frz evaporator 5 030 259 0000 Front enclosure 6 3516271 Valve expansion R404a 7 3516073 Coil...

Page 22: ...ud Condenser Coil 4 3526997 Compressor Danfoss TF4CLS 5 2194787 Start Capacitor 3516446 Comp Relay Danfoss 6 3516322 Filter Dryer 7 075 231 0030 Condensate Pan 8 3516454 Condenser Coil Key Part Number Description 000 BN5 0054 Assembly 1 2HP Cond Low Hot gas 1 3516554 Blade Fan 9 00 2 2160019 Guard Fan Wire 3 2162716 Motor Fan 16W 115V CW 4 3516324 Cutout High Pressure 5 3527001 Compressor SC12CLX ...

Page 23: ...HP Condenser Med 1 3516554 Condenser fan blade 2 2160019 Condenser fan guard 3 2162716 Condenser fan motor 115V 4 3516462 Capacitor start run assy 5 3527026 Compressor Danfoss SC12MLX 6 3516331 Hi pressure switch 7 3516322 Filter Drier 8 075 231 0031 Pan Condensate 9 3516455 Condenser coil Replacement Part Assemblies continued Key Part Number Description 000 BN5 0053 Assembly 1 3HP Cond w rec hg 1...

Page 24: ...194787 Capacitor start 280mfd 2194788 Capacitor start 320mfd 3516454 Coil Cond 1 5 1 4 3526997 Comp 1 5hp 115 60 r404a 3527000 Comp nf7cls 115v 60hz 3516322 Drier filter 2 inlet 2160020 Guard Fan 7 25 2162717 Motor fan 9w 115v cw 3516193 Regulator pressure 1 2 3516446 Relay Comp Danfoss 3516438 Relay comp ovld nf7clx 3516225 Valve exp frz 1 4ton 359 478 003E Panel louver 15 0 ptb 359 478 003D Pane...

Page 25: ...ce Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch Microprocessor Control Fan Delay Defrost Termination Switch Water Level Sensor Probe Compressor Start Components and Overload Protector Door Hinges Locks and Gaskets Defrost Timer Condensate Element Therm...

Page 26: ...F18 Series Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 26 Notes ...

Page 27: ...F18 Series Service and Installation Manual 27 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com Notes ...

Page 28: ...7 13 9291454 Thank you for choosing Delfield Help is a phone call away Help our team of professional courteous customer service reps by having your model number and serial number available at the time of your call 800 733 8829 Model ________________________ S N _______________________ Installation Date ________________ For a list of Delfield s authorized parts depots visit our website at www delfi...

Reviews:

Related manuals for F18MC39A