Part Number: 9291460  11/17

Installation 

Section 2

F5 Counter Installation For 36” & 48” Units

Installation Dimensions

Counter Cutout

32.62” x 18.62” (83cm x 47cm)

2 Louver Cutouts

22” x 11” (56cm x 28cm)

Max distance between counter 
top and louver cutout

4.00” (10cm)

11.00”

(28cm)

18.62”

 (47cm)

32.62”

 (83cm)

22.0”

 (56cm)

4.0” (10cm)

Max

11.00”

(28cm)

13.00”

(33cm)

Air duct dimensions

to match condenser face

1.  Install partitions between F5 refrigerated display case 

and other electrical appliances if they are located in the 

same cabinet. Partitions must fully extend front to back 

and top to bottom.

2.  Install a GFCI receptacle a minimum of 14” (36cm) up 

from the cabinet bottom inside the partitions.

3.  The unit requires airflow to the compressor. Two 

louvers are provided with each unit.
NOTE: Any restriction to the proper air flow will void the 

compressor warranty.

•  Louver cut-outs are 22” x 11” (56cm by 28cm).
•  143in2 (923cm2) is required at both the intake and 

discharge.

•  Cut-outs are to begin a maximum of 4.00” (10cm) 

from the counter-top.

•  Install the louvers on the front and back of the 

cabinet. 

Discharge Air

Fresh Air

Louver

Louver

Condenser

4.  Place the condensing unit through the counter cutout.
5.  Construct a 13” x 11” (33cm x 28cm) air duct (not 

provided) connecting the condenser face to the louver. 

This will prevent recirculation of discharge air.

11.00”

(28cm)

18.62”

 (47cm)

32.62”

 (83cm)

22.0”

 (56cm)

4.0” (10cm)

Max

11.00”

(28cm)

13.00”

(33cm)

Air duct dimensions

to match condenser face

Summary of Contents for F15MC48D-E

Page 1: ... Installation Operation and Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual Part Number 9291460 11 17 F5 and F15 Series Refrigerated Display Cases ...

Page 2: ...Never use flammable oil soaked cloths or combustible cleaning solutions for cleaning nWarning This product contains chemicals known to the State of California to cause cancer and or birth defects or other reproductive harm Operation installation and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers crystalline silica and or carbon monoxide Inhalation o...

Page 3: ...ounter Installation For 60 72 Units 11 Electrical Service 12 Voltage 12 Ground Fault Circuit Interrupter 12 Rated Amperages Horsepower Voltage Power Cord Chart 12 Drain Connections 13 Refrigeration 13 Remote Option Installation 14 F5 Remote Models 14 F15 Remote Models 14 Section 3 Operation Refrigerated Display Cases 15 Display Lock Operation 15 115Volt Power Switch 16 115Volt Light Switch 16 115V...

Page 4: ...enance General Cleaning 21 Interior Cleaning 22 Gaskets 22 Preventing Blower Coil Corrosion 22 Exterior Cleaning 22 Drain 22 Cleaning The Condenser Coil 23 Cleaning The Condensate Evaporator 23 Remote Models Only 23 Door Maintenance 23 Doors With Hinges 23 Sliding Doors 23 ...

Page 5: ... E F15SC72D E Serial Number Information The serial number is on the identification plate that also includes the model number Self contained F5 series identification plate is located near the condensing unit The serial number on all self contained F15 series units is located behind the compressor housing Always have the serial number of your unit available when calling for parts or service Warranty...

Page 6: ...6 Part Number 9291460 11 17 General Information Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...

Page 7: ...perate this equipment in outdoor areas The location selected for the equipment must meet the following criteria If any of these criteria are not met select another location Units are intended for indoor use only The location MUST be level stable and capable of supporting the weight of the equipment The location MUST be free from and clear of combustible materials Equipment MUST be level both front...

Page 8: ... 57 145cm F5PC60DV 60 152cm 33 38 85cm 57 145cm F5SC60DV 60 152cm 33 38 85cm 57 145cm F5MC72DV 72 183cm 31 5 80cm 57 145cm F5PC72DV 72 183cm 33 38 85cm 57 145cm F5SC72DV 72 183cm 33 38 85cm 57 145cm Self Contained Serview F15MC48DV 48 122cm 31 5 80cm 78 198cm F15PC48DV 48 122cm 33 38 85cm 78 198cm F15SC48DV 48 122cm 33 38 85cm 78 198cm F15MC60DV 60 152cm 31 5 80cm 78 198cm F15PC60DV 60 152cm 33 38...

Page 9: ...ew F15MC48D E 19 6ft2 18209cm2 22 3ft3 631L 9 15ft3 259L F15PC48D E 21 4ft2 19881cm2 25ft3 708L 9 15ft3 259L F15SC48D E 21 4ft2 19881cm2 24 3ft3 688L 9 15ft3 259L F15MC60D E 25ft2 23226cm2 28 4ft3 804L 12 13ft3 343L F15PC60D E 27 3ft2 25363cm2 31 9ft3 903L 12 13ft3 343L F15SC60D E 27 3ft2 25363cm2 31ft3 878L 12 13ft3 343L F15MC72D E 30 5ft2 28335cm2 34 6ft3 980L 18 04ft3 511L F15PC72D E 33 3ft2 30...

Page 10: ... a minimum of 14 36cm up from the cabinet bottom inside the partitions 3 The unit requires airflow to the compressor Two louvers are provided with each unit NOTE Any restriction to the proper air flow will void the compressor warranty Louver cut outs are 22 x 11 56cm by 28cm 143in2 923cm2 is required at both the intake and discharge Cut outs are to begin a maximum of 4 00 10cm from the counter top...

Page 11: ...net bottom inside the partitions 3 The unit requires airflow to the compressor Two louvers are provided with each unit NOTE Any restriction to the proper air flow will void the compressor warranty Louver cut outs are 22 x 11 56cm by 28cm 174in2 1123cm2 is required at both the intake and discharge Cut outs are to begin a maximum of 4 00 10cm from the counter top Install louvers on the front and bac...

Page 12: ...n to energize our equipment If code requires the use of a GFCI GFI then you must follow the local code The circuit must be dedicated sized properly and there must be a panel GFCI GFI breaker We do not recommend the use of GFCI GFI outlets to energize our equipment as they are known for more intermittent nuisance trips than panel breakers RATED AMPERAGES HORSEPOWER VOLTAGE POWER CORD CHART Display ...

Page 13: ... Display Base Display Self Contained Drop In F5MC36DV N A 4780 N A 425 32oz F5PC36DV N A 4780 N A 750 32oz F5SC36DV N A 4780 N A 510 32oz F5MC48DV N A 5335 N A 520 32oz F5PC48DV N A 5335 N A 900 32oz F5SC48DV N A 5335 N A 750 32oz F5MC60DV N A 6900 N A 600 48oz F5PC60DV N A 6900 N A 1050 48oz F5SC60DV N A 6900 N A 714 48oz F5MC72DV N A 7450 N A 690 48oz F5PC72DV N A 7450 N A 1200 48oz F5SC72DV N A...

Page 14: ...om End Front Of Unit J Junction Box R Refrigeration Lines 0 25 Liquid 0 37 Suction D 0 50 I D Drain R D J 3 75 10cm 3 75 10cm F5 Typical Mechanical Access Plan View F15 REMOTE MODELS 1 75 4cm 1 00 2 5cm C Front Of Unit J Junction Box R Refrigeration Lines 0 25 Liquid 0 37 Suction D 0 50 I D Drain R D D J 3 75 10cm 30 00 76cm 3 75 10cm F15 Typical Mechanical Access Plan View ...

Page 15: ...quipment nWarning Damp or wet hands may stick to cold surfaces nWarning Maximum weight for shelves is 75 pounds Overloading shelves can damage equipment or cause bodily injury nWarning Do not block the supply and return air grills or the air space around the air grills Keep plastic wrappings paper labels etc from being airborne and lodging in the grills Failure to keep the air grills clear will re...

Page 16: ...r fan as well as the evaporator fan will remain off until this initial defrost is complete This initial defrost cycle may take up to 35 minutes to complete 3 The display will continue to read dEF for an additional 30 minutes while the cooling cycle cools the box to the set temperature 4 Then the digital thermostat will display box temperature 5 The temperature control will cycle the compressor eva...

Page 17: ...ay Operation V V Press upper or lower right button Display show actual set point blinking If buttons untouched for 3 seconds returns to normal Increase set point by pressing upper button Max value depends on parameters in control Decrease set point by pressing lower button Min value depends on parameters in control If buttons untouched for 3 seconds returns to normal and stores new set point Press...

Page 18: ... device Under severe overloading conditions or in the event of a condenser fan failure or a plugged or blocked condenser this device may shut down the refrigeration system This device will automatically reset but determining the cause of the high pressure condition should be investigated by a qualified refrigeration technician Caution In attempting to adjust the pressure control you can do damage ...

Page 19: ...sh the stand by button lower left button to enter into the display menu 5 Scroll to CFu using the up down arrows and push the stand by button lower left button to enter the display unit menu 6 F should be displayed indicating Fahrenheit Use the down arrow to change it to C for Celsius and hit the stand by button lower left button to enter the change 7 Push the defrost button upper left button to m...

Page 20: ...d condenser this device may shut down the refrigeration system This device will automatically reset but determining the cause of the high pressure condition should be investigated by a qualified refrigeration technician Caution In attempting to adjust the pressure control you can do damage to your unit Please contact KitchenCare 1 844 724 2273 or your local service agent Delfield is not responsibl...

Page 21: ...se sharp objects or tools to remove ice or frost Do not use mechanical devices or other means to accelerate the defrosting process Caution Maintenance and servicing work other than cleaning as described in this manual must be done by an authorized service personnel General Cleaning nWarning When using cleaning fluids or chemicals rubber gloves and eye protection and or face shield must be worn Cau...

Page 22: ...ces with a damp cloth rinsed in water to remove dust and dirt from the outside of the unit Always rub with the grain of the stainless steel to avoid marring the finish If a greasy residue persists use a damp cloth rinsed in a mild dish soap and water solution Wipe dry with a clean soft cloth Never use steel wool or abrasive pads for cleaning Never use chlorinated citrus based or abrasive cleaners ...

Page 23: ...eavy use doors the hinges may become loose If this happens tighten the screws that mount the hinge brackets to the frame of the unit Loose or sagging doors can cause the hinges to pull out of the frame which may damage both the doors and the hinges In some cases this may require qualified service agents or maintenance personnel to perform repairs SLIDING DOORS Standard With Door Lock Clean the tra...

Page 24: ...7 Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge designs and lean manufacturing tactics are powered by deep knowledge operator insights and culinary expertise All of our products are backed by KitchenCare our aftermarket repair and parts service CLEVELAND CONVOTHERM DELFIELD FITKITCHEN FRYMAS...

Reviews: