Installation
Section 2
8
Part Number: 9294839 03/17
Electrical Service
DANGER
Check all wiring connections, including factory
terminals, before operation. Connections can become
loose during shipment and installation.
n
Warning
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.
VOLTAGE
All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
• The equipment must be grounded.
• A separate fuse/circuit breaker must be provided for
each unit.
• Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for each
unit.
GROUND FAULT CIRCUIT INTERRUPTER
Ground Fault Circuit Interrupter (GFCI/GFI) protection is
a system that shuts down the electric circuit (opens it)
when it senses an unexpected loss of power, presumably
to ground. Manitowoc does not recommend the use of
GFCI/GFI circuit protection to energize our equipment.
If code requires the use of a GFCI/GFI then you must
follow the local code. The circuit must be dedicated, sized
properly and there must be a panel GFCI/GFI breaker. We
do not recommend the use of GFCI/GFI outlets to energize
our equipment as they are known for more intermittent
nuisance trips than panel breakers.
RATED AMPERAGES, HORSEPOWER, VOLTAGE & POWER CORD CHART
Maximum 10ft (3m) cord with plug.
Glass Door Models
Solid Door Models
Amps
HP
Voltage, Cycle, Phase
NEMA Plug
Refriger
at
ors
1 S
ec
tion GBR1P-G(H),
GBSR1P-G(H),
GCR1P-G(H)
GBR1P-S(H),
GBSR1P-S(H),
GCR1P-S(H)
4.2
0.22
115, 60, 1
5-15p
2 S
ec
tion GBR2P-G(H),
GBSR2P-G(H),
GCR2P-G(H)
GBR2P-S(H),
GBSR2P-S(H),
GCR2P-S(H)
6.0
0.33
115, 60, 1
5-15p
3 S
ec
tion GBR3P-G,
GBSR3P-G,
GCR3P-G
GBR3P-S(H),
GBSR3P-S(H),
GCR3P-S(H)
6.5
0.355
115, 60, 1
5-15p
Fr
eez
ers
1 S
ec
tion
NA
GBF1P-S(H),
GBSF1P-S(H),
GCF1P-S(H)
7.2
0.55
115, 60, 1
5-15p
2 S
ec
tion
NA
GBF2P-S(H),
GBSF2P-S(H),
GCF2P-S(H)
10.0
0.68
115, 60, 1
5-15p
3 S
ec
tion
NA
GBF3P-S(H),
GBSF3P-S(H),
GCF3P-S(H)
14.7
0.55 (x2)
115, 60, 1
5-20P