background image

6000XL Series Service and Installation Manual

17

For customer service, call (800) 733-8829, (800) 733-8821, Fax (888) 779-2040, www.delfield.com

Delfield

®

Delfield warrants to the original purchaser-user, subject to the 

limitations and exclusions set forth below, that the ABS interior of the 

Delfield models identified above will be free of manufactured defects 

for as long as the equipment is owned by the original purchaser-user 

and is in operation.

What is covered.

The interior liner of the 6000XL Series refrigerators are covered 

against manufactured defects under normal use.  For purposes of 

this Warranty, interior liner is defined as the portion of the interior 

liner which is made of ABS material.  This warranty applies only to 

products sold and installed after March 1, 2000 in the United States, 

Canada, Puerto Rico, and Mexico.  For purposes of this warranty, 

lifetime is defined as the expected usable life for the equipment of 12 

years.

Delfield’s Obligation

Limited strictly to shipping OEM replacement parts or repair kits 

for any covered ABS interior.  A Delfield authorized service dealer 

and Delfield’s Service Department must confirm the liner defect 

has occurred under normal conditions and is not due to misuse 

as defined below.  All decisions regarding the ABS interior shall be 

made by Delfield’s Service Department and shall be binding upon 

the parties.  No labor or service charges or allowances are covered 

by this warranty.  Warranty service must be performed by a Delfield 

approved authorized service agent.

User Responsibility

The product must be installed, cleaned and maintained as described 

in the Service and Installation manual which is furnished with the 

product.  Only approved replacement parts may be used.  Failure 

to adhere to the requirements of this paragraph may void warranty 

coverage.

Procedures

All claims for replacement parts or repair kits must be made through 

a Delfield Parts Depot or an authorized Delfield dealer.  The defective 

part invoice must be returned to Delfield within 15 days after the 

date of service to be eligible for warranty coverage.  All claims 

must include the model number, serial number, an original date of 

installation and customer identification.  Use of parts other than 

original Delfield replacement parts will not be covered.

Exclusions

This warranty does not cover labor, service, charges for travel time, 

mileage, or premium charges.  This warranty also does not include 

defects resulting from:

• 

Operation of the product beyond the specification set forth in the 

Service and Installation Manual.

• 

Failure to clean and maintain the product as described in the 

Service and Installation Manual.

•      Installation of the product in a manner other than as set forth in

        the Service and Installation.

• 

Use of installation of replacement parts not approved by 

Delfield; or

• 

The introduction hot items directly onto the ABS liner.

This warranty is in lieu of all other warranties or guarantees of 
any kind, express or implied, except Delfield’s One Year Parts 
and One year Labor Warranty.  ANY IMPLIED WARRANTIES OR 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE 
ARE HEREBY DISCLAIMED AND EXCLUDED.  IN NO EVENT SHALL 
DELFIELD BE LIABLE FOR INCIDENTAL OR CONSEqUENTIAL 
DAMAgES OF ANY kIND OR NATURE, OR FOR ANY DEFECT 
RESULTINg IN WHOLE OR IN PART FROM MISUSE, ALTERATION, 
IMPROPER INSTALLATION OR INADEqUATE MAINTENANCE OF THE 
PRODUCT OR ANY PART THEREOF.

No part or assembly which has been subject to accident, alteration 

or misuse, or which has not been installed or serviced in accordance 

with the Operation Manual furnished with the product, or which is 

from equipment on which the serial number has been altered or 

removed, shall  be covered by this warranty.

Manufacturers Limited Lifetime Warranty-ABS Liner

Summary of Contents for 6125XL-S

Page 1: ...are Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 Refrigerators and Freezers Effective Date December 2007 IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS Delfield ...

Page 2: ...tents Serial Number Information Even though most equipment is shipped crated care should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the exterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the e...

Page 3: ... 5 33 2 1923 20 F 12 5 454 5 15p 6076XL SH S G GH 115 16 0 66 5 48 3 2092 2488 20 F 12 5 12 5 622 5 20p 6176XL S SH 115 208 230 15 0 66 5 48 3 1516 1923 20 F 12 5 12 5 622 14 20P MODEL VOLTAGE AMPS STORAGE CAPACITY FT3 SHELF CAPACITY FT2 REQUIRED BTU HR EVAP TEMP R 404A CHARGE OZ SHIPPING WEIGHT NEMA PLUG TYPE 6025XLR SH S G GH 110 2 0 20 15 1 2092 20 F 12 5 274 5 15p 6125XLR S SH 110 2 0 20 15 1 ...

Page 4: ...k into the hinge 9 Reinstall the plastic screw covers removed in step 2 10 Reinstall the door by reversing step 1 Installation Location Units represented in this manual are intended for indoor use only Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents A fully loaded 6000XL series can weigh as much as 1500 pounds Reinforce the floor as nec...

Page 5: ...the thermostat knob The switch controls power to the frame heater to minimize condensation around the door opening Press the switch to the 0 position to conserve energy If excessive condensation is observed on the door opening press the switch to the position red portion of the rocker will be visible Refrigeration Defrost Cycle Refrigerator Whenever the refrigerator is plugged in and the control h...

Page 6: ...ance the condenser fins must be cleaned of dust dirt and grease regularly It is recommended that this be done at least every three months If conditions are such that the condenser is totally blocked in three months the frequency of cleaning should be increased Clean the condenser with a vacuum cleaner or stiff brush If extremely dirty a commercially available condenser cleaner may be required Stai...

Page 7: ...become loose If it is noticed that the door is beginning to sag it may become necessary to tighten the screws that mount the hinge brackets to the frame of the unit If the doors are loose or sagging this can cause the hinge to pull out of the frame which may damage both the doors and the door hinges In some cases this can require qualified service agents or maintenance personnel Drain Maintenance ...

Page 8: ...COMPRESSOR BLK FRAME HEATERS NOTES 1 CONTROL CIRCUIT 5 3 RELAY COMPRESSOR LIGHT INCANDESCENT 1 1 2 3 2 1 2 3 3 1 2 3 BOX CONTROL ENERGY SAVER BLK BLUE 1 1 2 3 2 1 2 3 3 1 2 3 CONTROL TEMPERATURE 4 H BLK 2 L C 1 3 L W 5 N 6 F IF USED LED DISPLAY M START WINDING 14 10 FAN CONDENSER BLK W IN D IN G R U N 12 EVAPORATOR HOUSING MOTOR EVAP FAN SENSOR CABINET AIR EVAP COIL SENSOR M W BLK BLK W W W 11 STA...

Page 9: ...RESSOR LIGHT INCANDESCENT 1 1 2 3 2 1 2 3 3 1 2 3 BOX CONTROL ENERGY SAVER BLK BLUE 1 1 2 3 2 1 2 3 3 1 2 3 CONTROL TEMPERATURE 4 H BLK 2 L C 1 3 L W 5 N 6 F IF USED LED DISPLAY M STAR WINDING 14 10 FAN CONDENSER BLK W IN D IN G R U N 12 EVAPORATOR HOUSING MOTOR EVAP FAN SENSOR CABINET AIR EVAP COIL SENSOR M W BLK BLK W W W 11 START GROUND MOTOR PROTECTOR COMPRESSOR 13 CAPACITOR CONTROL BOX START ...

Page 10: ...4125 GROUND R U N W IN D IN G TEMPERATURE DOOR FRAME FLUORESCENT LAMP BALLAST FLUORESCENT FLUORESCENT FLUORESCENT LAMP SWITCHES SWITCH ENERGY SAVER FAN MOTOR EVAPORATOR M LAMP LAMP HEATERS FRAME HEATERS BLK W 1 1 2 3 2 1 2 3 3 1 2 3 CONTROL MOTOR PROTECTOR BLK LED DISPLAY IF USED M FAN CONDENSER COMPRESSOR 14 FLUORESCENT LAMP ASSEMBLY LAMP BALLAST FLUORESCENT DOOR FRAME FLUORESCENT RELAY COMPRESSO...

Page 11: ...CH W W WINDING PROTECTOR 12 13 FAN RELAY F 6 M HEATER RELAY H 4 EVAPORATOR FAN DEFROST HEATER C 1 CONDENSOR FAN M LED DISPLAY CONDENSOR FAN DEFROST HEATER EVAPORATOR FAN DOOR FRAME LINEVOLTAGE 115 60 1 SEE NAMEPLATE FOR MAXIMUM FUSE SIZE ENERGY SAVER SWITCH HEATER RELAY 1 1 2 3 2 1 2 3 3 1 2 3 COMPRESSOR RELAY CONTROL TEMPERATURE LED DISPLAY IF USED 3 L EVAP COIL SENSOR SENSOR CABINET AIR 1 C FAN ...

Page 12: ...HES DOOR BLK HINGE DOOR RED 1 1 2 3 2 1 2 3 3 1 2 3 CONTROL TEMPERATURE 4 H BLK 2 L C 1 3 L W 5 N 6 F IF USED LED DISPLAY SWITCHES STRIPES WITH BLUE EVAPORATOR HOUSING MOTOR EVAP FAN SENSOR CABINET AIR W W EVAP COIL SENSOR M LIGHT INCANDESCENT W BLK BLK W W W POWER BOX SPLICE NUT WIRE PLUG DOOR FRAME HEATERS NOTES CONTROL CIRCUIT 5 3 RELAY COMPRESSOR LIGHT INCANDESCENT 1 1 2 3 2 1 2 3 3 1 2 3 P HI...

Page 13: ... Series Service and Installation Manual 13 For customer service call 800 733 8829 800 733 8821 Fax 888 779 2040 www delfield com Delfield Refrigeration Package parts diagram 7 5 6 1 9 4 14 11 12 18 15 17 16 3 ...

Page 14: ...752 Door lock 3978018 Shelves 2194791 Cable 2194792 Display Freezer One section Item Number Part Number 50Hz Part Description 2 kit 2194783KT 2194964KT Control ETC1 Kit 3 2190152 Switch energy saver 4 2184181 Cord power 5 2162715 2162719 Motor fan evaporator 6 3516274 Fan blade evaporator 1 3516436 Coil evaporator 7 3516429 Valve refrigerant TXV 8 3516205 Clip TXV bulb mounting 19 2194785 2194967 ...

Page 15: ...Two section Item Number Part Number 50Hz Part Description 2 kit 2194783KT 2194964 Control ETC1 Kit 3 2190152 Switch energy saver 4 2184181 Cord power 5 2162715 2192719 Motor fan evaporator 6 3516274 Fan blade evaporator 1 3516436 Coil evaporator 7 3516429 Valve refrigerant TXV 8 3516205 Clip TXV bulb mounting 19 2194785 2194967 Heater defrost 20 9321629 Clip defrost heater mounting 21 2194953 Swit...

Page 16: ...be reimbursed under warranty unless pre approved with a Service Work Authorization from Delfield You must submit the number with the service claim LABOR OF 1 HOUR IS ALLOWED TO REPLACE Thermostat Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Hi limit Thermal Protector Switch Fan Delay Defrost Termination Switch Compressor Start Components and Overload Protector Door Hinge...

Page 17: ... paragraph may void warranty coverage Procedures All claims for replacement parts or repair kits must be made through a Delfield Parts Depot or an authorized Delfield dealer The defective part invoice must be returned to Delfield within 15 days after the date of service to be eligible for warranty coverage All claims must include the model number serial number an original date of installation and ...

Page 18: ... APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is requested prior to the arrival in the Delfield factory of the part claimed to be defective the Original Purchaser must accept delivery of the replacement part of a C O D basis with credit being issued after the part has been received and inspected at D...

Page 19: ...6000XL Series Service and Installation Manual 19 For customer service call 800 733 8829 800 733 8821 Fax 888 779 2040 www delfield com Delfield NOTES ...

Page 20: ...ted in the U S A Thank you for choosing Delfield Help is a phone call away Help our team of professional courteous customer service reps by having your model number and serial number available at the time of your call 800 733 8829 Model _____________________ S N ____________________ Installation Date _____________ For a list of Delfield s authorized parts depots visit our website at www delfield c...