18000 Series and CTP-NB

Service and Installation Manual

Please read this manual completely before attempting to install or operate this equipment! 

Notify carrier of damage!

 Inspect all 

components immediately. See page 3.

CTP-NB

Countertop Condiment Rail

18000-PTB

Pizza Tables with Raised Rail

18000-BUC

Work Tables

Effective May 2003

IMPORTA

NT INFOR

MATION

READ BEF

ORE USE

PLEASE S

AVE THES

E INSTRU

CTIONS!

CAUTION

Summary of Contents for 186114 BUC

Page 1: ...ting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 3 CTP NB Countertop Condiment Rail 18000 PTB Pizza Tables with Raised Rail 18000 BUC Work...

Page 2: ...PECIFICATIONS 18699 PTB MODEL NUMBER H P OF DOORS 18000 PTB series pizza tables with raised rail 18648 PTB 18660 PTB 18672 PTB 18691 PTB 1 27 19 27 2 27 2 27 1 19 3 27 OF SHELVES 1 2 2 3 3 1 4 1 3 1 2...

Page 3: ...is connected to the proper power source A protected circuit of the correct voltage and amperage must be run for connection of the line cord or permanent connection to the unit Self contained units wi...

Page 4: ...a condenser fan failure or a plugged or blocked condenser this device may shut down the refrigeration system This device will automatically reset but determining the cause of the high pressure conditi...

Page 5: ...ERANT CHARGES AND PRESSURE CONTROL SETTINGS All Delfield refrigerated models come equipped with 115 volt 60 cycle single phase refrigeration units The refrigeration valves are open and ready to operat...

Page 6: ...89 773 3210 www del eld com 6 WIRING DIAGRAM 18000 PTB SERIES L1 L2 CONDENSING UNIT ON OFF SWITCH ON 115 VOLT MODELS ONLY L2 IS THE NEUTRAL POWER CORD PROVIDED ON SELF CONTAINED MODELS G PRESSURE CONT...

Page 7: ...ld com L1 N BASE COIL 1 POWER SWITCH POWER CORD STANDARD ON ALL MODELS G CONDENSING UNIT BASE COIL 2 PRESSURE SWITCH CONTROLS ONLY THE CONDENSING UNIT where used WIRING DIAGRAM 18000 BUC SERIES POWER...

Page 8: ...SYSTEM 18000 BUC SERIES WRAPPED RAIL THERMOSTAT THERMOSTAT EXPANSION VALVE EXPANSION VALVE LOW PRESSURE CONTROL EVAPORATOR COIL EVAPORATOR COIL COIL HI PRESSURE SAFETY SWITCH CONDENSING UNIT SOLENOID...

Page 9: ...ice and Installation Manual 9 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www del eld com TUBE FOR THERMOSTAT BULB WRAPPED RAIL THERMOSTAT CONDENSING UNIT ON OFF SWITCH REFRIG...

Page 10: ...6173 Evaporator fan guard 3516095 Evaporator coil 3516273 Expansion valve base 1 4 ton HI 404A 3516273 Expansion valve rail 1 4 ton 404A 3516102 Solenoid valve 1 2 ODF 3516103 Solenoid coil 120v 21939...

Page 11: ...REPLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switc...

Page 12: ...O CUSTOMER AT THE AUTHORIZED SERVICE CENTER S THEN APPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is re...

Page 13: ...affect its quality or ef ciency or if the serial number has been altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where...

Page 14: ...18000 and CTP NB Series Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www del eld com 14 NOTES...

Page 15: ...18000 and CTP NB Series Service and Installation Manual 15 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www del eld com NOTES...

Page 16: ...toll free 1 800 272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performanc...

Reviews: