background image

Manual 

        

 

 Page 4 

IMPORTANT SAFETY PRECAUTIONS

 

 

IMPORTANT: 

Please read the following instructions before installing and operating this equipment. 

 

DANGER 

 

THIS EQUIPMENT CAN BE HAZARDOUS TO OPERATOR SAFETY AND ONLY AUTHORIZED 
PERSONNEL WHO HAVE READ AND UNDERSTAND THE INSTALLATION AND OPERATION 
MANUAL SHOULD  
BE PERMITTED TO OPERATE THIS EQUIPMENT. DO NOT LEAVE WAND UNATTENDED 
WHILE EQUIPMENT IS RUNNING.  

Failure to follow all cautionary warnings and procedures may result in serious or fatal injury and/or 
property damage including, but not limited to: fire, severe burns, concussion from explosion, 
electrocution, scalding, penetration by pressurized water, chemical reaction, asphyxiation, cuts, 
contusions, laceration, and loss of body parts and/or life. 

 

DO’S 

 

1.  ALWAYS WEAR SAFETY GLASSES, GOGGLES or FULL FACE SHIELD; GLOVES, and when 

spraying acids WEAR RAIN GEAR. NEVER RUN ACIDS THROUGH THE PUMP ON THIS 
EQUIPMENT.  

2.  USE ONLY THE SAME SIZE NOZZLE SUPPLIED WITH THIS EQUIPMENT.  

3.  CHECK YOUR BATTERY FOR WATER LEVELS AND MAINTAIN A GOOD CHARGE.  

4.  USE ¾" (inch) x 50' (foot) GARDEN HOSE FOR WATER SUPPLY-.  

5.  USE A CLEAN FUEL CAN FOR REFUELING UNIT.  

6.  USE CLEAN DIESEL FUEL OR KEROSENE.  NO ADDITIVES. Fill fuel tank each evening.  This 

will help minimize condensation in fuel tank, and prolong fuel pump life.  

7.  Always follow chemical manufacturer’s recommendations in use of chemicals with this 

equipment. Immediately after using chemical solutions through this equipment, flush thoroughly 
with clear water.  

8.  Disconnect all electrical power before performing any maintenance on this equipment.  

9.  Make sure positive is always positive and negative is always negative to keep from shorting out.  

10. When storing this equipment in freezing weather conditions, this equipment must be drained 

thoroughly; and the plumbing system charged with a 50% solution of permanent type antifreeze. 
Antifreeze should be used when the equipment is not in service for prolonged periods or is being 
transported in freezing weather.  NOTE: Antifreeze must be flushed out of equipment thoroughly 
before any cleaning project begins. Failure to do so could result in damage to paint or chemical 
attack on painted surfaces.  

11. Use a water softener on your water system if it is high in mineral content (HARDNESS).   Failure 

to do so will result in lime build-up in plumbing systems.  

12. Use only manufacturer approved components when replacing parts on this equipment.    Failure 

to do so may create operating conditions that are hazardous to personal health, safety, and will 
void the warranty.  

13. Use only recommended oil in pump.  

Summary of Contents for KING BRUTE PN 09301 A

Page 1: ...Manual Page 1 Pressure Washers and Accessories KING BRUTE PN 09301 A Operators Manual and Parts Lists Delco Pressure Washers LIT KING DEL Rev1 11 07...

Page 2: ...atisfy claims of the appropriate warranty provisions Normal wear items include but are not limited to Valves and Seals which are not covered by this warranty This Warranty replaces all other warrantie...

Page 3: ...ected by moving parts Electric Motors if applicable One 1 year from date of first start up Burners hot water machines One 1 year from date of first start up Hot Water Burner Coil hot water machines Fi...

Page 4: ...uel tank each evening This will help minimize condensation in fuel tank and prolong fuel pump life 7 Always follow chemical manufacturer s recommendations in use of chemicals with this equipment Immed...

Page 5: ...t solvents etc 12 DO NOT screw the pop off valve all the way in to prevent leaking or dripping 13 DO NOT adjust the unloader regulator valve on trigger control units to a pressure in excess of 200 PSI...

Page 6: ...ng fuel or diesel fuel without anti gel additives 3 VENTING THE UNITS If the unit is to be used in an enclosed area it must be vented out The Draft Regulator on oil fired units and chimney must be sam...

Page 7: ...nozzle tip into the cleaning gun 4 Close the soap valve turn fully clockwise 5 Securely hold the cleaning gun and turn the switch to position 1 pump 6 The recommended method of cleaning is A Wet enti...

Page 8: ...ECK DAILY 1 Check oil level in pump 2 Fill fuel tank at the end of each day s use to prevent condensation build up in fuel system 3 Fill soap container 4 Check oil level in engine THINGS TO CHECK WEEK...

Page 9: ...maximum heating and emission control 3 FUEL FILTER Clean or replace every 400 hours or 3 months whichever comes first or as needed This will help prolong fuel pump life and burner efficiency DESCRIPT...

Page 10: ...Service the fuel pump once every 50 hours or 3 months by cleaning the fuel strainer screen A clogged strainer or fuel filter will cause fuel pump starvation and dry the fuel pump up The ONLY lubricati...

Page 11: ...and coil inlet 2 Connect about four feet of hose with screen to suction side of a low pressure auxiliary pump 3 Connect a discharge hose between the low pressure auxiliary pump discharge side and the...

Page 12: ...age Worn crankcase seals Replace crankcase seals Oil leaking in area of crankshaft Worn crankshaft seal Bad bearing Replace damaged seals Replace bearing Excessive play in the end of the crankshaft Wo...

Page 13: ...Manual Page 13 Notes...

Page 14: ...15 PPA1516 PistonPin 3 16 PPA1517 Gasket 1 17 PPA1518 Screw 6 18 PPA1519 CrankcaseCover 1 19 PPA1520 ConnectingRod 3 20 PPA1521 GuidingPiston 3 21 PPA1522 O Ring 3 22 PPA1523 Washer 3 23 PPA1524 Pist...

Page 15: ...er 1 5 PPA1564 AdjustmentBarrel 1 6 PPA1565 RollPin 1 7 PPA1567 SpringGuide 1 8 PPA1568 UpperPlate 1 9 PPA1569 Spring 1 10 PPA1570 Lower Plate 1 11 PPA1572 Piston 1 12 PPA1573 O Ring 2 13 PPA1574 Pist...

Page 16: ...8 962139 1 Mounting Screws 1 4 20NC x 5 8 9 29606A 1 Blower Wheel R W B only 10 29609A 1 Coupling 11 197216 1 Fuel Unit 12 962219 4 Mounting Screws 1 4 20 NC x 7 8 13 193107 1 Pump Nozzle Port Fittin...

Page 17: ...Manual Page 17 ELECTRICAL SCHEMATIC 12VDC...

Page 18: ...Manual Page 18 GUNVALVE AND HOSE ASSEMBLY COMPONENT LOCATOR...

Page 19: ...a Aerografica 5 2 QC 381 22 O Ring O Anillo 6 1 192278 Quick Coupling Socket 3 8 Manguito de Acomplamiento R pido 3 8 7 1 DH 477 50 Hose 3 8 x 50 ft 3000 PSI Tubo Flexible 3 8 x 50 ft 3000 psi 8 1 QC...

Page 20: ...Manual Page 20 GC 590 40 GUNVALVE COMPONENT LOCATOR...

Page 21: ...GC 764 41 Cap Funda Tapa 12 1 GC 764 38 Valve Spring Muelle de V lvula 13 1 GC 764 36 Valve Ball V lvula de Bola 14 1 GC 764 32 Valve Seat Asiento de la V lvula 15 2 GC 764 30 O Ring Empaque O 16 7 G...

Page 22: ...1111 E Lake Francis Dr Siloam Springs AR 72761 1 800 BUY DELCO...

Reviews: