PRELIMINARY DIAGNOSIS FLOW
CHART
2-2. UNDERCHARGE SYMPTOMS
• Slow or no cranking
• Low voltmeter reading
• Dim lights/slow turn signal flashers
2-2
CHARGE BATTERIES
LOOSE
CHECK DRIVE BELT
MISSING
TIGHTEN BELT
TO MFG.
TENSION SPECS
OK
OK
CHECK PULLEYS
FOR LOCKED
BEARINGS
OK
OK
LOCKED
REPLACE BELT
REPAIR DEFECTIVE
COMPONENT
SLOW
CRANK ENGINE
OK
OK
START VEHICLE
CK. ALTERNATOR
VOLTAGE & OUTPUT
(PAGE 3-8)
OK BUT
DISCHARGED
CK. CRANKING
CIRCUIT
PAGE (3-2)
DEFECTIVE
DEFECTIVE
REPAIR AND
VERIFY REPAIR
CK. STARTER
SOLENOID
CIRCUIT
(PAGE 3-4)
SEE STARTER
REPLACEMENT
DETERMINATION
(PAGE 3-6)
REPAIR WIRING
CIRCUIT - VERIFY
REPAIR
CK. ALTERNATOR
VOLTAGE & OUTPUT
(PAGE 3-8)
TEST BATTERIES
(PAGE 3-1)
OK
new diagnostic manual 4/5/05 9:47 AM Page 2-2