background image

Preventive maintenance

Preventive maintenance

Preventive maintenance

Preventive maintenance

DeLaval milk meter MM15

1111 Every 300 hours

Every 300 hours

Every 300 hours

Every 300 hours

At farms where the cleaning temperature is 
above 80° C and where aggressive acid or 
alkaline detergents are used, the valve seal 
must be changed more often.
We recommend an interval of 300 hours

300 hours

300 hours

300 hours clean-

ing time.
Note! 

Note! 

Note! 

Note!  Overdosing standard detergents will 
also cause this problem. A swelled and wrin-
kled sealing may cause incorrect measuring of 
the milk flow. It is therefore vital that the sealing 
always is functioning properly.

2222 Once a year

Once a year

Once a year

Once a year

Replace rubber parts (1- 5) in the milk 
meter. Spare parts kit. 

98510380

The valve seal (2) should be replaced twice 

twice 

twice 

twice 

a year

a year

a year

a year together with the liners when used in 
conditions not described above.

3333 Yearly service

Yearly service

Yearly service

Yearly service

Yearly service should be performed by an De-
Laval serviceman (including replacement of 
rubber parts).

4444 Disassembly

Disassembly

Disassembly

Disassembly

21

61

24

DeLaval milk meter MM15

DeLaval milk meter MM15

DeLaval milk meter MM15

DeLaval milk meter MM15

161 Preventive maintenance

1 (9)

© DeLaval 2012.All rights reserved. 
Printout from Memoviewer 11/6/2012.

Summary of Contents for MM15

Page 1: ...w It is therefore vital that the sealing always is functioning properly 2 2 2 2 Once a year Once a year Once a year Once a year Replace rubber parts 1 5 in the milk meter Spare parts kit 98510380 The...

Page 2: ...er and remove the diaphragm Press the locking clip of the meter cup 3 To avoid any unnecessary breakage follow 2 1 6 2 7 4 DeLaval milk meter MM15 DeLaval milk meter MM15 DeLaval milk meter MM15 DeLav...

Page 3: ...remove the milk tube carefully Remove the plug in the sampling outlet Remove the valve arm with gasket 6 Disconnect the vacuum tube from bottom of the valve housing Snap open the locks to the lid and...

Page 4: ...e next page Note Note Note Note The DeLaval milk meter MM15is an accurate measuring tool and should be handled very carefully 5 5 5 5 Reassembly Reassembly Reassembly Reassembly Put the milk meter tog...

Page 5: ...ch other See adjoining figure When instal ling the spoiler plate notice that two of these three legs must be placed between the two bars moulded inside the housing This is vital for a proper function...

Page 6: ...up and inlet When the milk meter has been completely assembled check by pressing F76 F76 F76 F76 F902 F902 F902 F902 The value should be 25 250 Leave the function by pressing F72 F72 F72 F72 6 6 6 6 F...

Page 7: ...sembly Reassembly Reassembly Assemble the inlet seal onto the inlet with the large tapered rib on the side next to the milk meter housing The opposite side of the seal has a smaller rounded rib which...

Page 8: ...p Turn and remove the bayonet to the strain gauge Pull out the strain gauge Disconnect the two connectors to the sole noid valve With the lid straight downwards slide it to the left to release it from...

Page 9: ...article No 98958801 4 Do the same with the other three wires When the electronic unit with the gauge has been replaced the milk meter must be cali brated and its accuracy must be checked 2 1 6 2 7 5 2...

Reviews: