LPR1
FPR1
LPR2
GANG 2
GANG 1
5
7
6
210213
Fig. 11: Rod reader on the last place
5: IRW
6: Exit
7 : Entrance
2.3.3.3 Function of rod reader for in-place ID
The accuracy of readings can be improved even
more with in-place ID. This means that a multi rod
reader is located on each cow place. Each cow
is specifically identified on each place. This sol-
ution makes the IRW redundant.
2.3.3.4 Function of rod reader for in place ID Parallel
parlours
When the entrance gate opens, the readers on
the first and third stall are activated. When the
first reader has read a transponder, the second
and the fourth readers are activated. When the
second cow is identified, the third and the fifty
readers are activated and the first cow is verified
and so on. When a cow is verified the reader is
turned off.
If there is a cow without transponder or missed,
the MPC will show ------.
A cow can be identified by more than one reader
and then the ALPRO logic finds out where she is.
When the exit gate or gang fronts are opened, the
milk weight is confirmed to the processor. When
the first cow in the next batch of cows is identified,
the milk meters are reset and the old cow num-
bers disappears.
DeLaval ALPRO ID Champion
General description
© DeLaval 2014.
2014-12-03, Version 5
18 (28)
85417601
Summary of Contents for ALPRO ID Champion
Page 2: ......
Page 4: ...DeLaval ALPRO ID Champion Table of contents DeLaval 2014 2014 12 03 Version 5 4 28 85417601 ...
Page 6: ... DeLaval 2014 2014 12 03 Version 5 6 28 85417601 ...
Page 26: ...DeLaval ALPRO ID Champion Disposal DeLaval 2014 2014 12 03 Version 5 26 28 85417601 ...
Page 28: ...DeLaval Box 39 SE 147 21 Tumba SWEDEN www delaval com ...