MAINTENANCE AND CLEANING

•  

Cleaning chrome

 Do not use abrasive, 

chlorine or acid-based cleaning products. 
Clean with soapy water using a cloth or a 
sponge.

•  

Frost protection

 Drain the pipes and 

operate the mixer several times to drain 
any remaining water.

MAINTENANCE

•  Mixer: regularly check (as often as  

necessary) the temperature selector and 
the mixer’s two internal seats on which the 
mixing key turns. Replace as necessary.

Replacing the solenoid valve:

• Shut-off the hot and cold water supply.
•  Deck-mounted models and wall-mounted 

TEMPOMATIC 4: loosen the screw      
     (fig. D) using a 2.5mm Allen key with-
out removing it totally, and remove the cap  
     (fig. D) by rotating slightly downwards.

•  Wall-mounted TEMPOMATIC 3: Loosen 

the screw     (fig. F) using a 2.5mm Allen 
key without removing it totally, and remove 
the spout (fig. F).

•  Remove the electronic unit     (fig. D, F) 

and disconnect the connector     (fig. D, F).

•  Using a 17mm socket      (fig. D, F) for  

TEMPOMATIC 3, and 13mm for  
TEMPOMATIC 4, unscrew the solenoid 
valve     (fig. D, F).

•  Install the new solenoid valve and  

carefully tighten, ensuring that the thread  
is not damaged.

•  Reconnect the connector     (fig. D, F) to 

the electronic unit without replacing the 
unit.

•  Reconnect the water supply and check that 

the valve opens/closes by activating the 
electronic cell. Check that the solenoid 
valve is watertight inside the mixer body. 
If there are any leaks, gently tighten the 
solenoid valve.

•  Replace the electronic unit and the cap.
•  Deck-mounted models and wall-mounted 

TEMPOMATIC 4: Carefully tighten the 
screw     (fig. D).

•  Wall-mounted TEMPOMATIC 3 mural: 

Carefully tighten the screws     (fig. F) on 
the wall-mounted TEMPOMATIC 3.

Replacing the 6V Lithium battery:

•  Low battery life     (fig. G, H), will prevent 

the solenoid valve operating and cause the 
LED, sited on the sensor on TEMPOMATIC 
4 or on the TEMPOMATIC 3 electronic 
model, to blink for 15 days.

•  Using a 2.5mm Allen key: loosen the 

screws     (fig. G, H) without fully removing 
them and remove the cap     (fig. G, H) by 
rotating slightly downwards.

• Remove the electronic unit     (fig. G, H).
•  Loosen the screw/s     (fig. G, H) (1 screw 

on the TEMPOMATIC 3, 2 screws on the  
TEMPOMATIC 4) to change the battery, 
leaving the washer in place.

•  Replace the assembly, carefully tightening 

the screws     (fig. G, H) (taking care not to 
damage the sensor).

11

13

12

14

15

16

17

15

11

12

18

11

13

14

19

11

Reviews: