THRU-WALL DISPERSER INSTALLATION

For permanent spa installations, 

DEL Ozone

 can supply a dispersion fit-

ting that is permanently installed in the spa wall. The thru-wall disperser 

is designed to provide excellent ozone saturation in the water while being 

rugged enough for heavy spa use.

 

Both sides of the spa wall must be ac-

cessible for installation. The ZO-151 Thru-wall disperser should be located 

as low in the spa as is conveniently possible.

1.

Drain the spa

, determine the location for the Thru-wall Disperser and 

drill a 1-1/8

 

diameter hole in the spa wall. Remove any rough edges in 

the hole and remove any drilling debris from the bottom of the spa.

Figure 3:  Thru-Wall Disperser Installation Diagram

2.Place the supplied gasket on the threaded side of the thru-wall disperser 

fitting. From the inside of the spa, place the fitting through the 1-1/8 

diameter hole in the spa wall. From the outside of the spa, install the 

plastic nut and tighten to make a water-tight assembly.

3. Attach the ozone supply tubing to the hose barb on the thru-wall dis-

perser fitting using the supplied hose clamp to secure in place.

4. Place the dispersion disc on the nose piece with the smooth side toward 

the nose piece and the textured side toward the thru-wall disperser 

fitting. Screw the nose piece into the front of the thru-wall disperser 

and hand-tighten.

10

Summary of Contents for Z0-151

Page 1: ...INSTALLATION OPERATIONS MANUAL FOR DELZONE Z0 151 PORTABLE PURIFIER MANUFACTURED BY 3428 Bullock Lane San Luis Obispo CA 93401 800 676 1335 4 0252 Rev B 050904...

Page 2: ...ne 9 Do not expose your pets to ozone 10 When used for water purification make sure that a If the electrical connection of the ZO 151 Portable Purifier is made directly to a spas electrical system be...

Page 3: ...t of Boats and RVs 7 Automobile Odors 7 Treatment of Fruits and Vegetables 8 Treatment of Food and Cooking Utensils 8 Portable Water Treatment 8 PERMANENT APPLICATIONS Spas and Pools 9 Thru Wall Dispe...

Page 4: ...Nice France where it was used to purify drinking water Today more than thirty countries use ozone systems to purify drinking water In fact Los Angeles has one of the larg est ozone water treatment pla...

Page 5: ...unit and its components The unit should include ZO 151 PORTABLE PURIFIER UNIT OZONE SUPPLY TUBING 15 FEET OZONE DISPERSION STONE SUCTION CUP 4 BALL CHAIN 4 ADHESIVE RUBBER FEET Connect ozone supply tu...

Page 6: ...the dispersion stone Locate the dispersion stone as high and as far from other objects as possible Figure 1 for example Turn on the Portable Purifier and or set the timer and leave the room Allow the...

Page 7: ...10 X 10 60 minutes BEDROOM Unpleasant odors 17 X 18 60 minutes Cigarette odors CLOSET AREA Shoes clothes with odors 4 X 4 45 minutes CLOTHES Mildew Musty locate dispersion 15 minutes stone near garme...

Page 8: ...odors 18 24 60 minutes Cigarette food odors 30 32 70 minutes Cigarette food odors 35 40 75 minutes Soured foods locate 15 minutes dispersion stone at bottom of garbage can BOAT INTERIOR Dust stale ai...

Page 9: ...treat in clean water with ozone for fifteen minutes PORTABLE WATER TREATMENT The ZO 151 Portable Purifier is specifically designed to purify water in emergency storage spas bathtubs fountains and wadi...

Page 10: ...feet from the spa or water enclosure and at twelve inches above the maximum water level Ensure that the location is out of the reach of children or anyone in the water 2 To mount the ZO 151 Portable...

Page 11: ...ough edges in the hole and remove any drilling debris from the bottom of the spa Figure 3 Thru Wall Disperser Installation Diagram 2 Place the supplied gasket on the threaded side of the thru wall dis...

Page 12: ...amp cartridge connection loose 5A Reconnect 6 Lamp burnt out 6A Replace lamp SYMPTOM Red indicator light OFF air pump working but no ozone bubbles in spa PROBABLE CAUSE CORRECTIVE ACTION 7 Leak in sys...

Page 13: ...t strain on wires connecting cover components 4 Separate the finned aluminum lamp cartridge from its mounting bracket It may require the use of a screwdriver to pry the unit loose as these clamps are...

Page 14: ...the purifier s exposure Disconnect Power before servicing the unit The filter can be removed and replaced by ac cessing it through the hole in the back of the purifier with a pair of tweezers or plie...

Page 15: ...ARE HEREBY DISCLAIMED AND e DEL Ozone SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR LOSS OF USE OF SUCH PRODUCTS LOST PROFITS DIRECT DAMAGES INDIRECT DAM AGES CONSEQUENTIAL DAMAGES AND OR incidental...

Page 16: ...15 Copyright 2004 DEL Ozone...

Reviews: