background image

Figure 4

 Component Locations (Eclipse-2 Shown).  Additional transformers are used on 240V models, which are not shown in this diagram. 

4D. Trouble Shooting

Knowledge of electrical applications is required for trouble shoot-

ing. Contact a certified electrician if you are unsure of your ability to 

service the equipment. Improper servicing will void generator war-

ranty. If any condition persists, call DEL at 800-676-1335, ext.  248 

for  technical assistance or visit our website at www.delozone.com.

Symptom:

 

“LED Indicator”

 not lit when pool system is on.

1.  No power to the ozone generator from the power source:

a.

  Check circuit breaker at the power distribution box.

b.

  Check for loose connections or wiring breaks from the 

power distribution box to the generator.

c.

  Fuse in the unit has blown and needs to be replaced.

2.  G.F.C.I. has tripped.*

a.

  Check  power  cord  and  reset  G.F.C.I.  (*If  G.F.C.I.  or 

breaker continues to trip after reset, call 1-800- 676-

1335, ext 248 for technical assistance).

Symptom:

 

Flowmeter

 not indicating flow.

1.  Injector not supplying adequate suction.

a.

  Check pump and ensure water is flowing through injector.

b.

  Check by-pass valve and adjust if necessary to obtain proper 

pressure differential in order to reestablish suction.

c.

  Check that injector is plumbed in the right direction.

d.

  Ensure that there is no debris clogged inside the injector.

2.  Tubing is impaired.

a.

  Check for kinks or clogs.

b.

  Check for cracks or cuts.

c.

  Check connections.

d.

  Check that the check valve is installed with the arrow 

pointing towards the injector.

e.

  Be sure that the check valve has not become fouled with 

debris. Disconnect the ozone tubing from the ozone gen-

erator and the check valve. With the pump running, test 

the end of the ozone tubing with your thumb, and feel 

for suction. Wash your hands immediately afterwards 

to remove any residual nitric acid that may be on the 

tubing.  If there is sufficient suction without the check 

valve, replace the check valve with a new one. 

Symptom:

 

LED Indicator has turned red.

a.

  This means that the power supply of that specific ozone 

module is no longer drawing power and needs to be 

replaced. Inside the Eclipse the modules are numbered 

from the bottom up. So on an Eclipse 4, the top ozone 

module is #4 and the bottom ozone module is #1. These 

correspond to the LED ozone indicators at the bottom of 

the Eclipse, numbered 1-4 from left to right. This should 

tell you which ozone module has failed. Refer to section 

4C3 for instructions on how to replace the correspond-

ing ozone module. If you are having difficulties, contact 

Del’s service department at 1(800)676-1335 ext. 248.

 

Note:

 it is normal for the LED indicators to shine red for 

several seconds as the system powers up. As long as they 

turn back to green several seconds after startup. This is 

caused by the electronics charging up to create ozone. 

Symptom:

 

Ozone tubing becomes yellow/brown and brittle.

a.

  The high concentration of ozone created by the DELZONE 

Eclipse family of corona discharge ozone generators , 

as well as environmental conditions like UV sunlight will 

tend to deteriorate the supplied ozone tubing. This is 

normal and acceptable, as long as the tubing doesn’t 

become cracked and leak. Because of this, DEL rec-

ommends replacing the ozone supply tubing and your 

check valve every year.  More ozone tolerant tubing is 

available through DEL, however, it is still required that 

you change your check valve annually. 

Symptom:

 

Cant get ball to stay on centerline of flowmeter.

a.

  The  flowmeter  provided  is  a  general  tool  to  setup 

flow to the ozone generator. Flow will vary depending 

on  pressures  across  the  injector,  and  therefore  can 

be  affected  by  things  such  as  filter  or  strainer  load

-

ing. The ozone generator’s efficiency is optimized at 

near  the  centerline  of  the  flow  meter.  However,  the 

DELZONE  Eclipse  ozone  generator  will  still  perform 

quite well at flows above and below the recommended 

range.  As  long  as  the  ball  is  moving,  and  not  stuck 

on  the  bottom  of  the  flowmeter,  you  should  be  fine.

DELZONE

®

 Eclipse 1, 2, & 4 Corona Discharge Ozone Generators

4

Summary of Contents for Eclipse-1

Page 1: ...DEL Ozone SAN LUIS OBISPO CA 93401 USA 800 676 1335 Fax 805 541 8459 111904 4 0308 Rev F Corona Discharge Ozone Generators 1 2 4 INSTALLATION OPERATION MANUAL...

Page 2: ...of the unit to permit connection to a minimum No 8 AWG 8 4 mm2 solid bond ing conductor between this point and any metal equipment metal enclosures of electrical equipment metal water pipes or conduit...

Page 3: ...of direct Sunlight Locate generator out of reach of sprinklers or drainage spouts Allow sufficient access for maintenance and all tubing and electrical wires Ozone generator should be installed at lea...

Page 4: ...the ozone supply tubing to the port marked OZONE OUT see Bottom View Figure 4 NOTE Plumbing the Ozone Line to the incorrect port will cause damage to the ozone generator 2D 4 Flowmeter Connect the flo...

Page 5: ...ely2years if the pool system operates 24 hours day 365 days of the year 4B 3 Regularly check the flowmeter for proper flow and inspect ozone supply tubing for cracks or wear Replace ozone supply tubin...

Page 6: ...valve replace the check valve with a new one Symptom LED Indicator has turned red a This means that the power supply of that specific ozone module is no longer drawing power and needs to be replaced...

Page 7: ...ssitated by faulty installation improper maintenance improper operation misuse abuse negligence accident fire repair materials and or unauthorized accessories c any such products installed without reg...

Page 8: ......

Reviews: