Figure 4
Component Locations (Eclipse-2 Shown). Additional transformers are used on 240V models, which are not shown in this diagram.
4D. Trouble Shooting
Knowledge of electrical applications is required for trouble shoot-
ing. Contact a certified electrician if you are unsure of your ability to
service the equipment. Improper servicing will void generator war-
ranty. If any condition persists, call DEL at 800-676-1335, ext. 248
for technical assistance or visit our website at www.delozone.com.
Symptom:
“LED Indicator”
not lit when pool system is on.
1. No power to the ozone generator from the power source:
a.
Check circuit breaker at the power distribution box.
b.
Check for loose connections or wiring breaks from the
power distribution box to the generator.
c.
Fuse in the unit has blown and needs to be replaced.
2. G.F.C.I. has tripped.*
a.
Check power cord and reset G.F.C.I. (*If G.F.C.I. or
breaker continues to trip after reset, call 1-800- 676-
1335, ext 248 for technical assistance).
Symptom:
Flowmeter
not indicating flow.
1. Injector not supplying adequate suction.
a.
Check pump and ensure water is flowing through injector.
b.
Check by-pass valve and adjust if necessary to obtain proper
pressure differential in order to reestablish suction.
c.
Check that injector is plumbed in the right direction.
d.
Ensure that there is no debris clogged inside the injector.
2. Tubing is impaired.
a.
Check for kinks or clogs.
b.
Check for cracks or cuts.
c.
Check connections.
d.
Check that the check valve is installed with the arrow
pointing towards the injector.
e.
Be sure that the check valve has not become fouled with
debris. Disconnect the ozone tubing from the ozone gen-
erator and the check valve. With the pump running, test
the end of the ozone tubing with your thumb, and feel
for suction. Wash your hands immediately afterwards
to remove any residual nitric acid that may be on the
tubing. If there is sufficient suction without the check
valve, replace the check valve with a new one.
Symptom:
LED Indicator has turned red.
a.
This means that the power supply of that specific ozone
module is no longer drawing power and needs to be
replaced. Inside the Eclipse the modules are numbered
from the bottom up. So on an Eclipse 4, the top ozone
module is #4 and the bottom ozone module is #1. These
correspond to the LED ozone indicators at the bottom of
the Eclipse, numbered 1-4 from left to right. This should
tell you which ozone module has failed. Refer to section
4C3 for instructions on how to replace the correspond-
ing ozone module. If you are having difficulties, contact
Del’s service department at 1(800)676-1335 ext. 248.
Note:
it is normal for the LED indicators to shine red for
several seconds as the system powers up. As long as they
turn back to green several seconds after startup. This is
caused by the electronics charging up to create ozone.
Symptom:
Ozone tubing becomes yellow/brown and brittle.
a.
The high concentration of ozone created by the DELZONE
Eclipse family of corona discharge ozone generators ,
as well as environmental conditions like UV sunlight will
tend to deteriorate the supplied ozone tubing. This is
normal and acceptable, as long as the tubing doesn’t
become cracked and leak. Because of this, DEL rec-
ommends replacing the ozone supply tubing and your
check valve every year. More ozone tolerant tubing is
available through DEL, however, it is still required that
you change your check valve annually.
Symptom:
Cant get ball to stay on centerline of flowmeter.
a.
The flowmeter provided is a general tool to setup
flow to the ozone generator. Flow will vary depending
on pressures across the injector, and therefore can
be affected by things such as filter or strainer load
-
ing. The ozone generator’s efficiency is optimized at
near the centerline of the flow meter. However, the
DELZONE Eclipse ozone generator will still perform
quite well at flows above and below the recommended
range. As long as the ball is moving, and not stuck
on the bottom of the flowmeter, you should be fine.
DELZONE
®
Eclipse 1, 2, & 4 Corona Discharge Ozone Generators
4
Summary of Contents for Eclipse-1
Page 8: ......