12
M
ULTIPLIER OIL LEVEL- MULTIPLIER OIL SUBSTITUTION
To refill or substitute the oil use only OIL SAE 140 EP, multiplier capacity: 0,28 l.
Refilling or replacement of oil must be made at the intervals prescribed in diagram “A”.
a) To verify oil level in the multiplier operate as follows:
1)
Put the multiplier in vertical position then verify oil level through the spy “B”.
2)
If the level is low, remove the plug “A” and refill with proper oil type. Use only new oil.
3)
When the level is correct replace and tighten plug “A”.
b) To substitute oil in the multiplier operate as follows:
1)
Remove the plug “A”.
2)
Put a container under the multiplier then remove the discharge plug “C”.
3)
When the multiplier is empty replace and tighten the discharge plug “C”.
4)
Fill oil through plug “A”.
5)
When the level is correct replace the plug “A”.
Summary of Contents for RES
Page 17: ...17 SPARE PARTS OPTIONS...
Page 18: ...18 MAIN FRAME RES 10...
Page 19: ...19 MAIN FRAME RES 15 20...
Page 20: ...20 MAIN FRAME RES 30...
Page 21: ...21 ROTATION GROUP RES 15 20...
Page 22: ...22 ROTATION GROUP RES 30...
Page 23: ...23 ARMS RES 10...
Page 24: ...24 ARMS RES 15...
Page 25: ...25 ARMS RES 20...
Page 26: ...26 ARMS RES 30...
Page 27: ...27 HYDRAULIC SYSTEM RES 10...
Page 28: ...28 HYDRAULIC SYSTEM RES 15...
Page 29: ...29 HYDRAULIC SYSTEM RES 20...
Page 30: ...30 HYDRAULIC SYSTEM RES 30...
Page 31: ...31 RES 50 SUMMARY TABLE...
Page 32: ...32 RES 50 TABLE 20...
Page 33: ...33 RES 50 TABLE 40...
Page 34: ...34 RES 50 TABLE 30...
Page 35: ...35 RES 50 TABLE 10...
Page 36: ...36 RES 50 TABLE 50...
Page 37: ...37 RES 50 TABLE 100...