DSH 95 R/C DSH 105 R/C DSH 135 R/C DSH 195 R/C DSH 265 R/C
Heating Pump
Heating Pump
Heating Pump
Heating Pump
Heating Pump
Btu/h;W
7000
9000
12000
18000
24000
Btu/h;W
7200
9500
12800
19000
24500
Btu/h.w
8.97
8.94
9.01
9.14
9
W/W
2.89
2.63
2.75
2.75
2.7
Liters/h
0.5
0.8
1
1.5
2.4
High
dB(A)
36
36
37
42
49
Med.
dB(A)
33
33
34
39
46
Low
dB(A)
29
29
32
36
42
dB(A)
50
50
52
58
58
V
198~264
198~264
198~264
198~264
198~264
Cooling
A
3.6
4.6
6.0
9.0
13.0
Heating
A
3.3
4.8
6.2
9.2
13.8
Cooling
W
780
1010
1330
1970
2600
Heating
W
730
1060
1360
2020
2800
Gram
R22
R22
R22
R22
R22
Compressor
Rotary
Rotary
Rotary
Rotary
Rotary
m
3
/h
430
430/430
530/530
800/850
1100/1100
Cross flow
Cross flow
Cross flow
Cross flow
Cross flow
Cooling
rpm
1270/1170/1000
1270/1170/1000
1270/1170/1000
1300/1220/1150
1300/1220/1150
Heating
rpm
1250/1150/1000
1250/1150/1000
1250/1150/1000
1300/1220/1150
1300/1220/1150
Dry
rpm
1000
1000
1000
1150
1150
Sleep
rpm
1000
1000
1000
1150/1150
1150
W
12
12
12
23
35
Propeller
Propeller
Propeller
Propeller
Propeller
rpm
895
895
860
850
840
W
25
20
31
55
55
Gas
Inches
Φ
9.52(3/8'')
Φ
9.52(3/8'')
Φ
12.7(1/2'')
Φ
12.7(1/2'')
Φ
15.88(5/8'')
Liquid
Inches
Φ
6.35(1/4'')
Φ
6.35(1/4'')
Φ
6.35(1/4'')
Φ
6.35(1/4'')
Φ
9.52(3/8'')
Connecting Wiring
1.0x3; 0.75x2
1.0x3; 0.75x2
1.0x3; 0.75x2
1.5x3; 0.75x2
4×0.75;2×0.75
m
2
6~10
9~16
15~23
20~35
30~50
Indoor
mm
718x240x180
718x240x180
770x240x180
900x280x202
1033x313x202
Outdoor
mm
600x500x232
600x500x232
700x552x256
820x605x300
820x605x300
Indoor
kg
7
7
8
11
14
Outdoor
kg
23
24
30
41
52
Indoor
mm
805×305×265
805x305x265
855x305x265
995x365x298
1103x400x300
Outdoor
mm
745x542x353
745x542x353
803x598x380
965x650x438
965x650x438
Indoor
kg
9
9
10
14
17
Outdoor
kg
26
27
34
45
58
3
O.D 16mm
Indoor air
circulation(Cooling/Heating)
Defrosting system
Evaporator
Capillary tube
Microcomputer controlled reverse system
Packing dimensions
(W x H x D)
Indoor fan motor output
Outdoor fan type
Outdoor fan speed
Outdoor fan motor output
Size x Core
number
Drainage Pipe
Technical Specifications
Fan System
Condenser
Refrigerating System
Refrigerant/Charge
Type
Hydrophilic & Louver Fin; Innergroover tube type (
φ
7)
Louver or Corrugated Fin; Innergroover tube type (
φ
9.52 or
φ
7)
Gross weight
Indoor fan type
Indoor fan speed H/M/L
Expansion device
Others
Suitable area
Net dimensions
(W x H x D)
Net weight
Connections
Connecting Pipe
Outdoor noise level
Electrical Data
Rated input
Power supply
220-240V~/50Hz/1P
Voltage Range
Rated current
Remote Controller
Moisture removal
Indoor noise level at
cooling
DEKKER
Air Conditioner Service Manual
Model No.
Type
COP for heating
Rated cooling capacity
Rated heating capacity
EER for cooling
Control type