Deka AVR45 Series Installation And Operation Manual Download Page 2

Safety Precautions

  Protective Equipment ......................................3

  Procedures ......................................................3

Receiving & Storage

  Receiving Inspection........................................3

  Unpacking ........................................................3

  Storage ............................................................3

Installation

  General ............................................................3

  Grounding ........................................................4

  Racks ..............................................................4

  Electric Code for Maintenance Access ............4

  Hardware Torque Requirements......................4

  

System Installation

  Cell Installation ..............................................5

  

Electrical Connection

  Connector Assembly......................................5

  

Final Assembly Check Procedure

................6

TABLE OF CONTENTS

System Installations

  Charge Voltage..............................................6

  Charge Current..............................................6

  Temperature Compensation ..........................6

  Cell Voltage....................................................6

  Equalize ........................................................6

  Battery Operation ..........................................6

  Rectifier Ripple Voltage ................................7

Record Keeping

................................................7

Maintenance

  Annual Inspection ............................................7

  Battery Cleaning ..............................................7

  Capacity Testing ..............................................7

APPENDIX A 

– Unigy II AVR45 Series Battery 

  Weight & Acid Volumes....................................8

APPENDIX B

– Voltage Compensation Chart

  Charge Current Limits......................................9

APPENDIX C

– System Layout Drawings ......10

Battery Maintenance Report

........................12

  

Fig. 1-1

2

IN REFERENCE TO THIS MANUAL:

- “Cell” is defined as an individual 2-volt unit.

- “Battery string” is defined as a series connected 

electrical system comprised of cells (individual 2-volt units).

Summary of Contents for AVR45 Series

Page 1: ...L California Proposition 65 Warning Batteries battery posts terminals and related accessories contain lead and lead compounds and other chemicals known to the state of California to cause cancer and b...

Page 2: ...ltage 6 Charge Current 6 Temperature Compensation 6 Cell Voltage 6 Equalize 6 Battery Operation 6 Rectifier Ripple Voltage 7 Record Keeping 7 Maintenance Annual Inspection 7 Battery Cleaning 7 Capacit...

Page 3: ...ure battery modules racks or cabinets to the floor 9 Connect support structures to ground system in accordance with applicable codes Procedures continued 10 The IEEE Standards contain additional infor...

Page 4: ...responsibility Racks Assemble racks in accordance with intended arrangement align with a level and bolt to floor Consult applicable rack assembly instructions for specifics Electric Code for Maintena...

Page 5: ...is required 2 Connectors cable lugs supplied with cells It is recommended all connectors cables be coated with a thin film of NO OX ID A grease 3 Install the cables loosely to allow for final alignmen...

Page 6: ...ltage times the number of cells per battery string The charger must be able to maintain the battery string voltage within 0 5 of the desired level at all times Charge Current Charge current should not...

Page 7: ...y of the DMM Digital Multimeter must be 05 on dc scale or better The DMM must be calibrated to NIST traceable stan dards Because float readings are affected by dis charges and recharges these readings...

Page 8: ...2 18 AVR45 17 60 27 1 26 4 76 13 65 6 19 5 46 2 47 AVR45 19 67 30 1 41 5 32 15 26 6 92 6 10 2 77 AVR45 21 74 34 1 55 5 89 16 87 7 65 6 74 3 06 AVR45 23 81 37 1 70 6 45 18 47 8 38 7 39 3 35 AVR45 25 88...

Page 9: ...70 59 0 14 2 272 57 2 13 2 274 55 4 12 2 276 53 6 11 2 278 51 8 10 2 280 50 Float C Voltage per F Battery 12mV per C AVR45 5 16 1 4 8 AVR45 7 24 1 7 2 AVR45 9 32 2 9 6 AVR45 11 40 2 12 1 AVR45 13 48 2...

Page 10: ...10 APPENDIX C System Layout Drawings Drawing are representation of a 12V 6 cell system 5 15 Plate Assembly 17 27 Plate Assembly...

Page 11: ...11 29 33 Plate Assembly...

Page 12: ...ct to change without notice No part of this document may be copied or reproduced electronically or mechanically without written permission from the company East Penn Manufacturing Co Lyon Station PA 1...