background image

 

  

preliminary_fcc_lca-500_manual_en_896322_v200428_rev_3.docx 

 

Disclaimer 

deister electronic GmbH is not able to supervise the observance of the instructions given in this manual as 

well as the conditions and methods used during installation, operation and maintenance of the electronic 

devices and components respectively. Therefore we disclaim liability and reject responsibility for any losses, 

damages or costs that are caused by misap- plication, installation, handling errors or faulty operation or 

related to the above in any other way. All our products are subject to current advancement, therefore we 

reserve the right for modifications without prior notice. 

 

All rights reserved. No part of this publication may be reproduced, stored in a retrieval sys- tem, or trans-

mitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without 

prior written permission of deister electronic GmbH. 

 

deister electronic GmbH reserves the right to make changes to any and all parts of this documentation 

without obligation to notify any person or entity of such changes. 

 

deister electronic GmbH

 

Hermann-Bahlsen Str. 11 

30890 Barsinghausen 

Germany 

 

Phone:  +49 (0) 51 05 - 51 61 11 
Fax: 

+49 (0) 51 05 - 51 62 17 

E-Mail:  

[email protected]

 

Web: 

www.deister.com 

 

Summary of Contents for LCA 500

Page 1: ...preliminary_fcc_lca 500_manual_en_896322_v200428_rev_3 docx www deister com LCA 500 Wiring and Installation Instructions...

Page 2: ...nt or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected...

Page 3: ...her way All our products are subject to current advancement therefore we reserve the right for modifications without prior notice All rights reserved No part of this publication may be reproduced stor...

Page 4: ...5 2 RS 485 IN Connector 8 5 3 RS 485 OUT Connector 8 5 4 Mainboard Terminal Connector 8 5 5 RS 485 Terminator Switches 9 6 Signalization Factory settings 9 6 1 Configuration via DeisterConfig 10 6 2...

Page 5: ...ansmits a constant wake up signal with a location code up to a range of 5 m 2 Technical Data Dimensions xH 175 x 53 mm Material ASA Protection class IP40 Operating temperature 5 50 C Relative humidity...

Page 6: ...6 preliminary_fcc_lca 500_manual_en_896322_v200428_rev_3 docx 3 Mechanical Dimensions 3 1 LCA 500 All dimensions in mm inch For LED explanation see chapter 6...

Page 7: ...manual_en_896322_v200428_rev_3 docx 4 Connectors Terminal Board LCA 500 Mainboard LCA 500 RS 485 IN Connector RS 485 OUT Connector I O Connector 1 1 1 Mainboard Connector Terminal Mainboard Connector...

Page 8: ...1 normal close contact 5 2 RS 485 IN Connector Pin Symbol Description 1 V Positive Power Supply 2 GND Ground 3 A RS 485 A non inverted Data Line 4 B RS 485 B inverted Data Line 5 SYNCIN Positive Sync...

Page 9: ...ination resistor B A 5 V 130 Ohm 680 Ohm 0 5 W 680 Ohm 0 5 W stubline max 5 m 16 feet cable length max 1200 m 4000 feet Example 680R 680R 130R 119R Technical data for baud rates up to 115 kBaud Max ca...

Page 10: ...re configurable 6 1 Configuration via DeisterConfig Autotrim is automatically triggered on every startup of the reader Connect the LCA 500 to a communication adapter e g SNG 3 Connect the communicatio...

Page 11: ...nary_fcc_lca 500_manual_en_896322_v200428_rev_3 docx The configuration data of the device is loaded from the device and will be displayed 6 2 Device Info Field Device Info contains information about t...

Page 12: ...guard timeout ms This is the time it takes for the locator to respond when a Need Guard transponder enters the field without its Guard Signal not polled If this option is activated the locator signal...

Page 13: ...13 preliminary_fcc_lca 500_manual_en_896322_v200428_rev_3 docx If the external triggering is deactivated again the locator must be restarted after saving in order for the option to be accepted...

Page 14: ...ter e g SNG 3 Connect communication adapter to a PC Supply locator with DC Voltage in the range of 12 24V Launch DeisterConfig exe The following start screen appears The content of the start screen de...

Page 15: ...d from the device and will be displayed In order to update the firmware of the device select Update firmware from the menu Device Select the folder where the firmware is stored After double clicking o...

Page 16: ...significant influence on the read range and may thus be used With growing distance between reader and an interference source the influence decreases Use only regulated power supplies deister electroni...

Page 17: ...nd don ts Do not place transponder in short circuit coil or in metal frame Install transponder in front of or behind the short circuit coil or metal Do not install reader directly on metal One meter d...

Page 18: ...the range of 125 kHz 868 MHz guarantees optimal performance The signal energy of one reader interferes with the read write range of another The signal energy from one reader does not inter fere with...

Page 19: ...19 preliminary_fcc_lca 500_manual_en_896322_v200428_rev_3 docx Notes...

Page 20: ...Tel 33 0 1 47 35 78 78 Fax 33 0 1 47 35 92 59 info fr deister com Great Britain deister electronic UK Ltd Stapleton Way Enterprise Park Spalding Lincolnshire PE11 3YQ Tel 44 0 1775 717100 Fax 44 0 17...