Display functions 

The display indicates both readings and alarms. Illustrated below are examples with icons and 
English language.  
 

 

Type, Hardware and software version. 
 
 
 
 
 

 

Fuel level, Oil pressure, water temp. and RPM. 
 
 
 
 

 

Service timer 1 and 2. 
 
Run hours. 
 
 
 
 

 

Press       to enter the list of active alarms. 
 

 

 

Active alarm list

. The alarm list pops up auto-

matically, when an alarm appears. When the ar-
row is present, more alarms are active. Press 

 to scroll through the list. Exit the list by press-

ing ESC. 
 
 

 

Press       to enter the parameter setting. 
 

 

 

Parameter example: D+ delay setting. Use 

 or 

 to scroll through the settings list. If change of 

settings is necessary, press       and enter the 
password. Then use 

 or 

 to change values. 

Use ESC to leave settings. 

 

 

 

Min. value           Actual value           Max. value 

 
 
 

 

GC-1F 

 

HW x.xx 
SW x.xx

 

Fuel level   

        80 % 

Oil press   

        2.0 bar 

Water 

 

        90°C 

RPM  

 

        0 

 

Alarm list

 

 

2 alarm(s) 

 

 

 

2 alarm(s) 

High Battery 

Ack 

 

Parameter 

 

 

D+ delay 

 

0.0 s                     10.0 s                      100.0 s

  1 

 

0 d   

  0 h 

  2 

 

0 d   

  0 h 

Run hours   

 

24 h  

Summary of Contents for GC-1F

Page 1: ...OPERATOR S MANUAL Push buttons LEDs Icon list Display readings Document no 4189340475C Gen set Controller GC 1F...

Page 2: ...GC 1F Operator s Manual DEIF A S Page 2 of 11 This description includes the following versions GC 1F SW version 1 2x x GC 1F 2 SW version 2 0x x or later...

Page 3: ...4 GENERAL PURPOSE 4 INTENDED USERS 4 CONTENTS OVERALL STRUCTURE 4 2 WARNINGS AND LEGAL INFORMATION 5 LEGAL INFORMATION AND RESPONSIBILITY 5 ELECTROSTATIC DISCHARGE AWARENESS 5 SAFETY ISSUES 5 FACTORY...

Page 4: ...n of the unit Intended users This Operator s Manual is mainly intended for the daily user On the basis of this document the operator will be able to carry out simple day to day procedures Contents ove...

Page 5: ...live electrical equipment Factory settings The unit is delivered with certain factory settings Given the fact that these settings are based on average values they are not necessarily the correct setti...

Page 6: ...Generator Assemblies where the suitability of the combination has been determined by Underwriters Laboratories These devices have been evaluated for fire and shock only The accuracy and or reliabilit...

Page 7: ...in AUTO mode the mode will change to MAN and the engine will stop Breaker OFF Breaker ON AUT AUTO running mode selector Enters value or ack nowledges alarm MAN Manual running mode selector Reset horn...

Page 8: ...relay Extra function Press and hold button 2 sec to see alarm list Normal display Scrolls the display up once Programming Increases setpoint value Normal display Scrolls the display down once Programm...

Page 9: ...e non acknowledged alarm s present Steady Active acknowledged alarm s present Additional alarm indication LEDs Flashing Active non acknowledged alarm s where output A or B is configured to LED 1 2 3 o...

Page 10: ...n alarm appears When the ar row is present more alarms are active Press to scroll through the list Exit the list by press ing ESC Press to enter the parameter setting Parameter example D delay setting...

Page 11: ...ters and setup please see the Installation Instructions i Reference Handbook The available parameters depend on the set options Some parameters can only be changed using the PC utility software USW fo...

Reviews: