DM-4 Gas/Hydro 

 

 

 

Application Notes, PCM TCP/IP port (WebArm)

 

 

 

DEIF A/S

  

Page 5 of 10 

 

 

3. Abstract 

 
 
The DM-4 offers TCP/IP communication, which may need to be changed (address etc.). This 
document is the instruction manual that tells how to carry out changes and which changes are 
available. 
 
Furthermore, it describes how to check the PCM module (WebArm module). 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DELOMATIC 4 Series

Page 1: ...APPLICATION NOTES PCM TCP IP port WebArm TCP IP setup Document no 4189340652A DELOMATIC 4 DM 4 GAS HYDRO ...

Page 2: ...NDED USERS 3 CONTENTS OVERALL STRUCTURE 3 2 WARNINGS AND LEGAL INFORMATION 4 LEGAL INFORMATION AND RESPONSIBILITY 4 ELECTROSTATIC DISCHARGE AWARENESS 4 SAFETY ISSUES 4 DEFINITIONS 4 3 ABSTRACT 5 4 CONFIGURATION OF THE PCM CARD 6 CHECK SOFTWARE VIA IP CONNECTION 6 CHECK SOFTWARE WITH TELNET 7 CHANGE OF PC IP CONFIGURATION 8 DM 4 IP ADDRESS 10 ...

Page 3: ...cases this would be a panel builder designer Naturally other users might also find useful information in this document Contents overall structure The document is divided into chapters and in order to make the structure of the document simple and easy to use each chapter will begin from the top of a new page Please make sure to read this handbook before working with the DM 4 controller and the gen ...

Page 4: ...ork with dangerous currents and voltages Therefore the installation should only be carried out by authorised personnel who understand the risks involved in working with live electrical equipment Definitions Throughout this document a number of notes and warnings will be presented To ensure that these are noticed they will be highlighted in order to separate them from the general text Notes Warning...

Page 5: ...5 of 10 3 Abstract The DM 4 offers TCP IP communication which may need to be changed address etc This document is the instruction manual that tells how to carry out changes and which changes are available Furthermore it describes how to check the PCM module WebArm module ...

Page 6: ...on Use a TCP IP cable to connect your PC to the DM 4 Ethernet port Open your internet browser Key in the IP address in the address field Click enter You now get the information screen from the PCM card Select Device Status You may be prompted for a name and password User name admin Password admin From factory the IP address is 192 168 2 21 ...

Page 7: ... The OS version will if correct display the date here Nov 15 13 556 03 GMT 2007 Alternative to using a web browser Check software with telnet Under Windows start prompt Select Run Write cmd and press enter The command prompt will appear Now start telnet Command telnet ip address example telnet 192 168 2 21 ...

Page 8: ... is the correct WebArm software exit to disconnect from PCM card The software has now been checked Change of PC IP configuration If it is not possible to establish connection the PC IP setting may have to be changed Select in windows START Settings Control panel Network connections Local area connection Properties Internet protocol TCP IP ...

Page 9: ...ot be used here Subnet mask 255 255 255 0 After this you can check the connection using ping In Windows Start Run Cmd In the prompt write ping 192 168 2 21 example use the relevant DM 4 IP address If successful the prompt looks like this Now the DEIF HMI BROWSER can be used and the user interface can be started Remember that you have to change back to original settings after finishing this check ...

Page 10: ...ddress for the DM 4 Note that the system has to be restarted before the change takes effect The default IP address is 192 168 2 21 The default netmask is 255 255 255 0 Example DEIF A S reserves the right to change any of the above When the IP address is changed only the new address can be used to access the DM 4 via TCP IP Make sure that you use a valid address if changing it ...

Reviews: