DEGREE C Rooster Sensor 100 User Manual Download Page 1

Rooster

 Sensor100 USER MANUAL 

 

 

 

 

  

Rooster

 TM

 Sensor100 USER MANUAL 62320MN000-A04      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This is proprietary information of Degree Controls Inc., contents are protected under US copyright laws © Degree Controls, Inc. 2021 

 

High Performance Air Velocity and 

Temperature Sensor

  

with Full-Color Touch Screen Display

 

 

Complete Kit includes: 

o

 

Sensor Display Panel 

o

 

Sensor Probe and Mounting Clamp 

o

 

Power Supply 

 

1.06 

Summary of Contents for Rooster Sensor 100

Page 1: ...ry information of Degree Controls Inc contents are protected under US copyright laws Degree Controls Inc 2021 High Performance Air Velocity and Temperature Sensor with Full Color Touch Screen Display Complete Kit includes o Sensor Display Panel o Sensor Probe and Mounting Clamp o Power Supply 1 06 ...

Page 2: ...robe Sensor 10 Boot Up Procedure 12 Access Tier Privileges USER EH S CERTIFIER 12 Set Change Passwords 13 Alarm Threshold Configuration 13 Alarm Troubleshooting 14 Alarm Controls 14 Night Setback 15 Alarm Ringback 15 Alarm Delay 16 Startup Delay 16 Latch Alarm 16 Alarm Tone Settings 17 Backlight Dimming 17 Airflow Settings 18 Airflow Sensitivity 18 Airflow Resolution 18 Volumetric Flow Settings 18...

Page 3: ...he RoosterTM Sensor100 uses a bright backlit display and contains many simple to use features and configuration capabilities built into an intuitive user interface that requires little to no training to learn Password protected access tiers ensure greater safety in a range of environments by limiting access to critical functions and system settings for specific authorized users The RoosterTM Senso...

Page 4: ...mat Home Settings System Time Date and Time Settings KEYPAD SOUNDS Users may toggle keypad beep sounds on and off Home Settings System Alarms Sound Key Beep ALARM VOLUME Users can toggle through low medium or high alarm volumes If logged in as an EH S or Certifier a global minimum volume threshold can be set This restricts a standard user from setting an alarm volume too low for particular facilit...

Page 5: ... AND DATA IMPORT EXPORT Firmware upgrades can be installed on site via USB flash drive See the USB Field Upgrade section for more information Users may also import export Rooster settings and export the event log through the USB interface CUSTOMIZABLE BOOT SCREEN Our engineers can configure your unit with a custom image or logo file 240x320 in portable network graphic png format to display on boot...

Page 6: ...ayed once duct diameter information has been entered see the Volumetric Flow Settings section of this manual for more information Home Settings System Advanced Airflow Resolution Rear Panel Layout for Advanced Connections Rear Panel View of RoosterTM Sensor100 Connection Description Connector Type Mating Connector Power Entry 2 Pin polarized Phoenix Contact Included and attached to AC DC power sup...

Page 7: ... present on the RoosterTM have some pins deactivated as these are reserved for future Rooster TM models designed for more advanced control functionality o Output Connectors Pins 5 6 o Input Connectors Pins 7 10 These pins should be non connected Alarm Module Size 82mm x 135mm x 19mm 3 2 x 5 3 x 0 7 without back plate LCD Display Area 57mm x 70mm 2 3 x 2 7 Airflow Velocity Range 30 4 000 fpm 0 15 2...

Page 8: ... will alarm when airflow drops below the NSB trip threshold but the alarm will be muted o Off default In this state when the night setback signal is asserted the Sensor100 will ignore it Alarm Output The RoosterTM alarms for airflow The alarm output is a relay outputs available on the output connection of the display module I O polarity logic of outputs may be reversed as well See the I O Polarity...

Page 9: ...allation Procedure 1 Determine mounting locations for the RoosterTM alarm module and sensor 2 Choose alarm module mounting method Wall Mount or Semi Flush 3 Mark the surface where the RoosterTM alarm module will be located and make the necessary drills cutout 4 Secure back plate 5 Mount the sensor See below for sensor installation 6 Feed power and sensor wire harnesses through the opening s and ma...

Page 10: ...p specifications and installation instructions C Clamp and Sensor Installation 1 Mark the sensor hole and screw positions per Step 1 of C Clamp installation figure below 2 Drill a 17 32 14mm hole through the surface you wish to install the sensor 3 Drill two pilot holes for the C Clamp fastening screws C Clamp Degree Controls P N 64500AS011 4 Secure the C Clamp with two screws not provided 5 Inser...

Page 11: ...the provided screw tighten and cinch the sensor into place Back View Front View Figure 4 C Clamp Figure 5 C Clamp Installation Figure 6 Airflow Direction Ensure that the sensor head is aligned correctly by positioning the arrow in the direction of airflow Step 1 Step 2 Step 3 Step 4 Step 5 ...

Page 12: ...pear with two system buttons and you will need to setup password protected access tiers for advanced system functions This is explained in the Access Tier Privileges section below Access Tier Privileges USER EH S CERTIFIER Users have the ability to customize their containment cabinets within a defined set of options for each authorization level There are three levels of access to the RoosterTM Use...

Page 13: ...gle between Metric or Imperial Air Velocity Units on Home Screen None Toggle ON OFF Keypad Sounds None Unlatch Alarm if Alarm Latching is set to Password EH S Set Change Passwords To change or set a password follow this GUI path to trigger the password change sequence Home Settings System Advanced Change Passwords You will have to enter an EH S or Certifier passcode to get access to the Advanced m...

Page 14: ... thresholds are assigned for night setback you may choose to set your alarm as audible or muted in the alarm controls menu below Home Settings System Alarms Sound Alarm Controls Night Setback 4 To quickly glance at threshold settings follow this menu path Home Settings Thresholds Threshold Info Alarm Troubleshooting Is your alarm failing to sound or clear as you intended You may need to verify tha...

Page 15: ... must go to the Threshold menu and select Adjust Thresholds Off Disables Night Setback mode Alarm does not enter Night Setback mode when relay is closed Alarm Ringback When an active alarm state is muted ringback is a useful safety feature to remind the user that the muted alarm is still active Whenever there is an active alarm state the red LED will flash for the entire duration of the alarm Ther...

Page 16: ...er 5 seconds if velocity readings are below the alarm trip threshold 10s Alarm is cleared after 10 seconds if velocity readings are above the alarm clear threshold Alarm is triggered after 10 seconds if velocity readings are below the alarm trip threshold Startup Delay The startup delay prevents an alarm from triggering until the workstation and ventilation systems have fully powered up and are op...

Page 17: ...mples 1 If the sensor becomes disconnected and Sensor Alarm is set to Tone 1 the audible alarm will play Tone 1 and the on screen alert banner will indicate Sensor Fault 2 If the sensor becomes disconnected and Sensor Alarm is set to Off there will be no audible alarm and the on screen alert banner will indicate Sensor Fault Backlight Dimming Brightness is adjusted via left and right arrows Actual...

Page 18: ...e uniform readout this can be configured at different settings up to 5 fpm or 05 m s Home Settings System Airflow Settings Airflow Resolution Airflow Resolution Definition 1 fpm Displayed units in FPM are rounded to 1 fpm This is the default setting 2 fpm Displayed units in FPM are rounded to 2 fpm 5 fpm Displayed units in FPM are rounded to 5 fpm 01 m s Displayed units in m s are rounded to 01 m ...

Page 19: ...enter the Duct Size screen Home Settings System Airflow Settings Volumetric Flow Settings Volumetric Flow Duct Size 7 Press the Shape button until the appropriate duct shape is displayed circular or rectangular 8 Press the Units button to display your choice of cm or inch units for entry of duct dimension s 9 Enter the dimension s of the duct diameter for circular shape height and width for rectan...

Page 20: ...lt to alarm when the relay is closed If this is toggled to Normally Closed NC then this logic is reversed Home Settings System Advanced I O Polarity Import Export EEPROM The user can save all current RoosterTM settings to a USB thumb drive for future use Importing the EEPROM configuration file to another RoosterTM in your facility ensures operational consistency and saves valuable setup time Plug ...

Page 21: ...latest in Rooster technology offers users a convenient soft reboot procedure for upgrading the operating system while maintaining existing calibration data and user settings This is available for a Rooster having firmware version 1 06 and later A Rooster with firmware preceding version 1 06 may be upgraded however existing calibration data will be lost and all settings may be reset to factory defa...

Page 22: ...wer failure or some other circumstance the existing firmware may be corrupted and the device may become nonfunctional Contact Degree Controls if your RoosterTM is inoperative as a result of an interruption during the firmware update procedure Soft Reboot from Info Screen Procedure 1 Insert the USB thumb drive into the left side of RoosterTM 2 Navigate to the Info screen and press the Upgrade butto...

Page 23: ...validate that the new firmware version was properly installed The firmware release information listed next to firmware should have changed to the most current build If this is not the case repeat the upgrade procedure Factory Reset Procedure The Master Reset will return the Rooster Sensor100 to its default alarm input output settings Time and date will be preserved during a factory reset The follo...

Page 24: ...Rooster Sensor100 USER MANUAL Rooster TM Sensor100 USER MANUAL 62320MN000 A04 24 GUI Map ...

Page 25: ...red by DegreeC Such parts components or products may be warranted by third parties on a pass through basis The foregoing remedies shall not apply to any product failure caused in whole or in part by i Buyer s failure to operate maintain or service the products in accordance with DegreeC s documentation ii any alteration modification or repair made to the products other than by DegreeC or iii use o...

Reviews: