Plate controls
1.
Left front
2.
Left back
3.
Right back
4.
Right front
Dual Zone
plate control
on Gemini CP
model only
Ringer timer
on Gemini CP model only
x
The ringer timer may be used for timing
a cooking period of up to 60 minutes.
x
First wind the timer by turning the knob
fully clockwise.
x
Return the knob to the desired time
period.
x
At the end of the this period the bell will
ring.
x
Note: If the timer is not first fully wound
the bell may not ring.
Hot surface indicator
Individual light for each
plate.
1 2 3 4
Electrical installation
This appliance must be earthed and the manufacturer and the seller do not
accept responsibility for any damage due to incorrect installation or electrical
connection.
Hobs with control panels
Earth leakage
This hob should not be connected through an earth leakage system.
Refer to S.A.N.S. 10142
Connection to the power supply
must be carried out by a licensed electrician, who will
ensure that the hob is correctly connected and safely earthed. The rated current is printed on
the serial number label attached to the base cover.
The hob must be connected to the mains through a double pole isolating switch which has a
minimum clearance between the contacts of 3 mm. in both poles.
A means for disconnection must be provided in the fixed wiring.
Note:
The appliance is not intended to be operated by means of an external timer or separate remote-
control system.
Hobs without control panels
Electrical connection is via connector blocks to the oven below the hob.
Please see the section pertaining to electrical connection as described in the oven manual.
Controls .
The plate controls for hobs without a control panel are located on the oven fascia