![Defy DHG931 Instruction Manual Download Page 13](http://html1.mh-extra.com/html/defy/dhg931/dhg931_instruction-manual_2464598013.webp)
Page 13
DANGER Risk of explosion and
suffocation!
The maximum
bottle size allowed in the house
is19 Kg
1
LP hose tip
2
Plastic hose
Leakage control at the connection point
•
Ensure that the control knobs on the hob
are in the OFF position.
•
Open the valve on the Gas bottle.
•
Using a small paint brush, apply some
soapy water to all the connections.
Manifold protection plug
Manifold protector plug removal:
The manifold protection plug is inserted into
the manifold at factory level in order to
protect the manifold from being
contaminated with debris. The manifold
protection plug must be removed when the
product is installed by the gas installer.
The red manifold protection plug can be
removed from the manifold by grabbing it
with your fingers or if necessary with the aid
of a small pair of pliers.
Manifold
•
If there is a leak, bubbles will appear.
•
If this happens, close the valve on the gas
bottle.
•
Check and tighten the connections
immediately.
•
Repeat the procedure to ensure that there
are no further leaks.
Installing the appliance
1. Remove burners, burner caps and grills
on the hob from the appliance.
2. Turning the hob upside down, place it on
a flat surface.
3. In order to avoid foreign substances and
liquids penetrating between the hob and
the counter, please apply the seal
supplied in the package on the contours
of the lower housing of the hob, making
sure that the seal does not overlap.
4.Apply the seal by bending it around the
corners as in the figure.
Make sure the seal is filled on the
base cover contours.
5. Turning the hob again, align and place it
on the counter.
6. Secure your hob to the counter by using
the clamp and the screws supplied.
(wooden spacers may be required).
*
min. 20 & max. 40 mm
1
Hob
2
Screw
3
Installation clamp
4
Counter
5
Seal
Caution:
Never use a naked
flame to check for gas leaks