Page 13
Make sure the putty is filled on the
base cover contours.
5. Turning the hob again, align and place it
on the counter.
6. Secure your hob to the counter by using
the clamp and the screws supplied.
(wooden spacers may be required).
*
min. 20 & max. 40 mm
1
Hob
2
Screw
3
Installation clamp
4
Counter
5
Putty
Rear view
Place burner plates, burner plate caps and
grills back to their seating after installation.
Making connections to different
holes is not good practice in terms
of safety since it can damage the
gas and electrical system.
1
LPG hose tip
2
Plastic hose
Leakage control at the connection point
x
Ensure that the control knobs on the hob
are in the OFF position.
x
Open the valve on the Gas bottle.
x
Using a small paint brush, apply some
soapy water to all the connections.
x
If there is a leak, bubbles will appear.
x
If this happens, close the valve on the gas
bottle.
x
Check and tighten the connections
immediately.
x
Repeat the procedure to ensure that there
are no further leaks.
Installing the appliance
1. Remove burners, burner caps and grills
on the hob from the appliance.
2. Turning the hob upside down, place it on
a flat surface.
Manifold protection plug
Manifold protector plug removal:
The manifold protection plug is inserted into
the manifold at factory level in order to
protect the manifold from being
contaminated with debris. The manifold
protection plug must be removed when the
product is installed by the gas installer. The
red manifold protection plug can be removed
from the manifold by grabbing it with your
fingers or if necessary with the aid of a small
pair of pliers.
Manifold
3. In order to avoid foreign substances and
liquids penetrating between the hob and
the counter, please apply the putty
supplied in the package on the contours
of the lower housing of the hob, making
sure that the putty does not overlap.
4. Apply the putty by bending it around the
corners as in the figure.