Page 15
Unless there is an abnormal condition,
do not attempt to remove the gas burner
taps. You must call an authorised
service agent if it is necessary to
change the taps.
New injectors have their position
marked on their packing or refer to the
Injector table.
Reduced gas flow rate setting for taps
1. Ignite the burner that is to be adjusted and turn the
knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust
the flow rate adjustment screw. For LPG (Butane -
Propane) turn the screw clockwise. For natural
gas, you should turn the screw
counter-
clockwise
once. The normal length of a straight
flame in the reduced position should be 6-7 mm
4. If the flame is higher than the desired position, turn
the screw clockwise. If it is smaller turn
anticlockwise.
5. For the last control, bring the burner to both the
high-flame and reduced positions and check
whether the flame is on or off.
Depending on the type of gas tap used in your
appliance the adjustment screw position may vary.
1
Flow rate adjustment screw
Important:
Read these
instructions for use
carefully so as to
familiarize yourself with
the appliance before
connecting it to its gas
container. Keep these
instructions for future
reference.
If the gas type of the appliance is
changed, then the rating plate that
shows the gas type of the unit must also
be changed.
Danger of fire: Do not
store items on the
cooking surface.
CAUTION:
The cooking
process has to be
supervised. A short term
cooking process has to
be supervised
continuously.
WARNING:
Unattended
cooking on a hob with fat
or oil can be dangerous
and may result in a fire.