Page 3
Flexible hose
- Not supplied.
•
Any hose that is used to connect the stove to the gas system shall comply with
SANS 1156-2 or BS 3212.
Temporary installation.
•
Flexible hose connection from the gas appliance to the cylinder can be made by the
user. Ensure that pipe clamps are tightened correctly and are of good quality.
Gas cylinder
- Not supplied.
•
For best results we recommend that gas cylinders with a minimum capacity of 19kg
be used.
Regulator
- Not supplied.
•
A 2,8 kPa LPG gas regulator which complies with SANS 1237 must be used.
Permanent installation.
•
The appliance may only be installed by a Qualified Gas Fitter who is registered with
the
LPGSASA
. (Liquid Petroleum Gas Association of Southern Africa)
•
All registered Gas Fitters are issued with an identity card which carries their
registration number. Make a note of this in the box below.
•
The Gas Fitter should also provide you with a written certificate after completion of
the work.
Failure to comply with the above will render the warranty invalid.
•
Before the installer hands over the installed appliance be sure that you fully
understand:
a) The position of the isolation or shut-off valve in the gas supply line to the appliance.
b) The requirements for safe operation of the appliance.
Note:
•
This appliance is supplied ex-factory with jets and air settings for use
with LPG gas only.
•
We strongly recommend that the changing of the jets and air flow
adjustment be carried out by a trained Defy technician.
Installer’s details to be filled in below
Safety
compliance with local requirements
Summary of Contents for DGS 150
Page 7: ...Page 7 Notes...