13
Fan
[rpm]
–
rotational
speed
of
flue
gas
fan
Auger
[s]
–
operation
time
of
endless
screw
Screen
displayed
with
a
button
:
Pressure
[mbar]
–
water
pressure
in
central
heating
system
Work
time
[h]
–
operating
time
of
stove
in
Normal,
Modulation
modes.
Ignitions
–
number
of
firing
up
cycles
Prod.Code.
–
product
code
Control of stove operation
First start-up of the stove
During
first
start
‐
up
of
the
stove
or
when
it
is
stated
after
refuelling
resulting
from
complete
combustion
of
pellet.
Turn
on
the
power
Switch
on
pellet
endless
screw
Menu
Customization
Manual
Load
using
option
ON
,
when
you
hear
a
sound
of
falling
pellet,
switch
off
using
OFF
option.
Switch
on
Rozpalanie/Firing
up
with
button.
The
stove
will
switch
to
firing
up
and
will
continue
operation
in
automatic
mode.
Stove start-up
Turn
on
the
power.
Press
button
.
The
stove
will
switch
to
firing
up
and
will
continue
operation
in
automatic
mode.
Operating power setting
In
Menu
customization
Power
Combustion
there
is
a
7
‐
stage
controller,
which
can
be
used
for
control
of
stove
maximum
power.
The
stove
is
operating
on
power
6
by
default,
that
is
it
uses
whole
power
for
heating
of
water.
This
status
is
indicated
by
a
letter
A
on
P1
indicator
of
controller
display.
When
user
decreases
power
in
the
menu
it
will
be
reflected
in
P1
index,
letter
M
will
appear
instead
of
letter
A
.
Decreasing
combustion
power
results
in
prolongation
of
time
for
reaching
of
set
water
temperature,
decreasing
at
the
same
time
portions
of
supplied
pellet.
Work cycle
After
initiation
of
the
firing
the
stove
switches
successively
to
the
following
operation
modes:
Checking
Probe
Firing
up
Stabilization
Operation
Modulation
Standby
Damping
Presented
cycle
is
repeated
automatically
to
maintain
constant
power
of
the
stove
and
temperature
of
water
in
stove.
During
operation
temperature
of
water
may
increase
or
decrease,
but
it
always
should
oscillate
around
the
set
value.
Stove shutdown
Stove,
in
any
operating
mode,
can
be
switched
off
by
button
,
what
results
in
automatic
switching
to
Damping
mode.
After
completion
of
this
cycle
the
stove
switches
to
Off
mode
and
in
this
mode
you
can
safely
shutdown
supply
of
the
stove.
Stove emergency shutdown
In
case
of
emergency
the
stove
can
be
immediately
switched
off
by
disconnecting
power
supply
‐
using
switch
or
pulling
out
the
plug
from
a
supply
socket.
A
small
part
of
pellet
in
burner
will
be
combusted
during
several
seconds
and
flame
will
be
damped.
Working time programming
The
stove
can
be
programmed
for
scheduled
operation
using
Menu
Customization
Chrono
Modality.
Selected
mode
causes
switching
on
and
off
the
stove
in
accordance
with
the
periods
set
in
Menu
Customization
Chrono
Program
with
a
programme
corresponding
to
the
given
mode.
Time
programming
details
are
described
in
the
chapter
Menu
Customization
,
subsection
Chrono
.
Informations
Exhaust T. [
o
C] 101
Boiler T. [
o
C]
65
Buffer T. [
o
C]
36
Fan [rpm]
0
Auger [s]
0.0
Informations
Pressure [mbar] 0
Work time [h]
65
Ignitions
11
Prod. Code: 562 0