1 - Apply a drop of medium thread locker to the start of the flap thread and the linkage part. 

 

 

 

 

 

 

2 - Tighten the linkage part with the sleeve 7900052 (tighten and lock the screw to 8 N.m). 

 

 

 

 

 

 

 

Assembling the flagpole: 

 
1 - Position the flag-holder cam on the groove of the connecting piece. 
2 - Slightly tighten the screw without blocking it. 
3 - Orient (OPEN) the flag holder in line with the handle. 
4 - Tighten the screw to a torque of 120 cNm. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Summary of Contents for DPX EBC

Page 1: ...MAINTENANCE MANUAL NM 283 Index 1 Page 1 15 April 2022 MANUAL BUTTERFLY VALVE Compact Inter Flange with IO LINK MVQ detection www definox com...

Page 2: ...VALVE SUB ASSEMBLY 5 5 DISASSEMBLING THE MANUAL SYSTEM 5 5 1 SEPARATING THE MANUAL SYSTEM 5 6 ASSEMBLING THE EBC MANUAL BUTTERFLY VALVE WITH IO LINK MVQ101 DETECTION 6 6 1 LIST OF PARTS FOR THE ASSEM...

Page 3: ...MAINTENANCE MANUAL NM 283 Index 1 Page 3 15 April 2022 1 CHANGE MANAGEMENT MODIFICATIONS INDEX DATE PAGES BY New edition 1 April 2022 G BEGAUD...

Page 4: ...us bodily injury or loss of life This can result in less serious injuries or damage to the equipment Electricity can result in serious bodily injury or loss of life This can result in less serious inj...

Page 5: ...TTERFLY VALVE SUB ASSEMBLY For disassembly reassembly and maintenance of DPX EBC sub assemblies refer to the maintenance manual NM 222 for DPX EBC 5 DISASSEMBLING THE MANUAL SYSTEM 5 1 SEPARATING THE...

Page 6: ...6 1 LIST OF PARTS FOR THE ASSEMBLY IO LINK MVQ101 Detection Hub Handle Assembly DPX connector for IO LINK MVQ101 7818992 ref 5 Double turn IO LINK IFM MVQ101 detector 7008450 4 CHC screws ref 6 4 scre...

Page 7: ...VALVE Apply a drop of medium thread locker to the start of the thread of the 4 CHC screws of the hub attachment valve lubrication instruction sheet NDT 020 Pay attention to the expiry date of the prod...

Page 8: ...x 1 Page 8 15 April 2022 Alignment of the hub handle assembly 1 Take the centring device 7900053 3 Tighten the 4 CHC screws 2 Position and screw in the centring device this allows alignment of the hub...

Page 9: ...thread and the linkage part 2 Tighten the linkage part with the sleeve 7900052 tighten and lock the screw to 8 N m Assembling the flagpole 1 Position the flag holder cam on the groove of the connecti...

Page 10: ...ion is or greater than 26 70 mm Take the measurement as close as possible to both sides of the flag Positioning of the MVQ of IFM 7008450 1 Apply a drop of medium thread locker on the start of the thr...

Page 11: ...MAINTENANCE MANUAL NM 283 Index 1 Page 11 15 April 2022 6 3 IO LINK MVQ101 DETECTOR SETTING When the valve is opened the OPEN position appears When the valve is closed the indicator remains BLACK...

Page 12: ...connected LED 4 Steady white Communication status OUT2 valve position closed LED 5 ring Steady yellow Switch status OUT1 Programmable colours default yellow and blue Steady blue Switch status OUT2 Fl...

Page 13: ...seconds remove the metal part the LED ring is lit in a steady yellow the communication threshold is set Close the valve Place a metal piece on top of the detector until the LED ring flashes blue Let t...

Page 14: ...l the LED ring flashes once briefly and then lights up again N B We are also at your disposal for the maintenance of your valves in our workshops or on site 6 4 SPARE PARTS IO LINK DETECTION HANDLE MV...

Page 15: ...A DEFINOX Beijing Stainless Steel Equipment Ltd No 18 Anningzhuang East Road HAIDIAN District BEIJING 100085 CHINA Phone 86 10 6293 4909 Fax 86 10 6293 4835 lk definox com cn The technical characteris...

Reviews: