6.8 - AC current sensor
Sensor type
Current transformer (Defi ne
Instruments ACCS-420/010)
Amperage range
Header selectable
100/150/200A; Overload 175/300/400A
respectively (continuous)
Output
(Representing 0–100% of full scale
input range)
ACCS-420 = 4–20mA DC loop powered
ACCS-010 = 0–10V DC
Power supply
ACCS-420 = Loop powered, 15–36V DC
ACCS-010 = Self powered
Accuracy
1% of full scale
Response time
250ms (10–90%)
Isolation voltage
2,000V
Frequency
50–60Hz
AC current sensors
The meter accepts input from a Defi ne
Instruments AC current sensor. Set the
jumper on the top of the current sensor
to the desired current range, as shown
(right).
AC Current Sensor
4−20mA
Powered by the
Meter
AC Current
Sensor
0−10V
Signal powered
Jump Range
0–100A
0–150A
0–200A