Power Supply / Charging

PosiTest AT-M

(manual)

Power Source: Built-in rechargeable NiMH battery**

~60 hours continuous with full charge

The built-in rechargeable NiMH batteries are charged using the
included USB AC power supply/charger. Ensure batteries are
charged prior to use. The battery icon will blink while the
instrument is charging and disappear when fully charged. The
charging process will take up to 14 hours depending on remaining
battery power.
Alternatively, the AC power supply or any computer USB port can
be used to power and charge the instrument.

**Do not attempt to remove or replace the PosiTest AT-M internal NiMH
battery pack. In the unlikely event power issues are experienced,
please contact our technical support for assistance.

PosiTest AT-A

(automatic)

Power Source: Built-in rechargeable NiMH battery

>200 pulls with full charge

The built-in rechargeable NiMH batteries are charged using the
included AC power supply/charger. Ensure batteries are charged
prior to use. The USB port will not charge or power the PosiTest
AT-A.
The charging process will take 2-3 hours depending on remaining
battery power. Alternatively, the AC power supply can be used to
power the instrument.

The

icon will display while the instrument is charging.

When fully charged the

icon will appear.

The PosiTest AT-A internal NiMH battery pack is user

replaceable. In the unlikely event power issues are experienced,
please contact our technical support or your local dealer for OEM
battery pricing, availability and detailed replacement instructions.

NOTE:

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for ATM50A

Page 1: ...Full Guide v 5 0 PosiTest AT A automatic PosiTest AT M manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 3: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 4: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 5: ...he nature of the fracture for each pull off test see pg 11 Fracture results are included in test reports Glue failure visible separation of the glue from itself the coating or dolly no coating visible...

Page 6: ...hes when the button is pressed To preserve battery life the instrument powers down after 5 minutes of no activity 1 Ensure the pressure relief valve is completely open turn counter clockwise OPEN 2 Pu...

Page 7: ...for the various dolly diameters are For optimum results prior to exceeding the priming pressure return the pump handle to its full upright position and then complete a single continuous stroke at the...

Page 8: ...ttons are used to navigate through menu options and adjust parameters Access Menu Select Power On Start Test Return to Main View Stop Test Power down hold for 5 seconds Screen Capture Press both butto...

Page 9: ...ew Swipe horizontally or use arrow keys to switch between views Pull Parameters pg 11 WiFi Bluetooth USB Status icons Pull Chart displays pressure over time Current Reading Touch Screen Display If rec...

Page 10: ...y batch is open the maximum pressure result is automatically stored into memory pg 13 Pass fail pull parameters date and time are also recorded The nature of the fracture cohesive adhesive glue batch...

Page 11: ...lay Views are represented by dots the solid dot indicates the current view Swipe horizontally to navigate between views or vertically to move between batch readings Alternatively the directional butto...

Page 12: ...d using the PosiTector App pg 18 Fractures are visually estimated and recorded as a percent of each The two layer example below illustrates a cohesive fracture within coating layer 1 and layer 2 visua...

Page 13: ...ohesive failure within layer 1 30 cohesive within layer 2 PosiTest AT A Examples Select Edit to set the number of layers and cohesive adhesive fracture details Use the buttons to adjust www GlobalTest...

Page 14: ...ing process closes the current batch and removes batch information from the display Removes a batch and associated measurements from memory Setup Menu Pull Parameters Dolly Size Select the dolly size...

Page 15: ...for use in horizontal or vertical positions Restores factory settings and returns the instrument to a known condition The following occurs All batches stored readings notes batch names and screen capt...

Page 16: ...ctory Optionally text txt files located in each batch folder provide access to measurement values Stored readings and graphs can be viewed or copied using universal PC Mac web browsers or file explore...

Page 17: ...ection range If the network is secure the password must be entered if unknown contact the Network Administrator Use the QWERTY keyboard to enter the password then press OK Select Connect to establish...

Page 18: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 19: ...tware or internet connection required USB Drive must be selected see pg 15 PosiSoft net a free web based application offering secure centralized storage of instrument readings Access your data from an...

Page 20: ...technical support for assistance PosiTest AT A automatic Power Source Built in rechargeable NiMH battery 200 pulls with full charge The built in rechargeable NiMH batteries are charged using the inclu...

Page 21: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 22: ...n If you need to return the instrument for service describe the problem fully and include reading results if any Be sure to include contact information including your company name company contact tele...

Reviews: