EN
defa.com
16
Set the required charging power
1.
Press the Mode Button to toggle between Normal mode/Low mode/High mode. The modes will
appear in the following order: Normal (default starting mode) → Low → High → Normal →.
2.
When setting the device to Low mode or High mode the Mode Button will be lit for 5 seconds
and then fade. The amount of bars on Charger Status Indication show which of the modes is
currently active.
3.
The Charger Status Indication will blink for 2 seconds until the change is effective, then stay lit.
i
NOTICE
If charging ends on Low mode, this setting will be stored until the next use. If
charging ends on High mode the setting will revert to Normal mode at the next use.
• Low mode: If Low mode is set, the charging level will be lower than normal. This might be
required if the fuse for the domestic outlet is lower than the rating of the product. Or if the
domestic outlets electrical circuit used for the portable charger is shared with other electrical
products.
• High mode: If High mode is set, the charging level will be higher than normal. The level will
automatically switch back to Normal mode after 120 minutes during one session (if High mode
is turned off for a while and then turned back on again, the 120 minutes are accumulated
during the whole session). If the control box or domestic plug becomes too hot during High
mode, the current level will automatically reduce until lower temperature is detected.
Charging power
Normal mode 13 A
High mode 15 A
Low mode, factory set 8 A