3.5 AC Power Connection
The EQ901 B does not have a power switch and can be left powered on, as power
consumption is very low. You also may power your EQ901 B from a switched outlet on your
receiver.
4. Setting Input Levels
The analog audio input levels are switchable between 0.9 Vrms and 2.0 Vrms to accommodate
use with most preamplifiers, amplifiers or receivers. If you are experiencing excessive signal
level or distortion, you may need to switch the unit to the 2.0 Vrms setting.
The EQ901 B model is shipped with the input levels preset to 0.9 Vrms.
0.9 Vrms position.
With this setting, the maximum input signal voltage allowed before clipping
the A/D convertor is 0.9 Vrms. This position is typically used when the EQ901 B is connected
between a preamp and a power amplifier.
2.0 Vrms position.
With this setting, the maximum input signal voltage allowed before clipping
the A/D convertor is 2.0 Vrms. This position is typically used when the EQ901 B is connected
in a tape recording loop (REC/in to PB/out).
Page 5
EQ901 B Series User Guide - Rev. 04012022 deercreekaudio.com