Part load heating mode efficiency (92/42/EEC) 

(return temperature 30 °C)

 

%

110.6

110.4

108.1

Part load heating mode efficiency (GB20665–

2015) (return temperature 30 °C)

 

%

108.0

107.8

107.9

(1) Factory setting

Tab.14 Gas and flue gas values

C140

 

 

C140 – 45

C140 – 65

C140 – 90

G20 gas consumption (H gas)

(1)

min.–max.

m

3

/h

0.9 - 4.4

1.3 - 6.6

1.5 - 9.1

Gas consumption G31 (propane)

(1)

min–max

m

3

/h

0.4 - 1.7

0.5 - 2.5

0.9 - 3.5

Gas resistance G20 (H gas)

(2)

max

mbar

1.0

2.0

2.5

NOx annual emissions G20 (H gas) O2 = 0%

 

mg/kWh 

(HHV)

33

29

41

Flue gas quantity

min–max

m

3

/h

12 - 60

18 - 90

22 - 125

Flue gas temperature

min–max

°C

30 - 67

30 - 67

30 - 67

Maximum counter pressure (Pn)

 

Pa

150

100

160

(1) Gas consumption based on lower heating value in standardised conditions: T=288.15 K, p=1013.25 mbar. Gag 30.33; G25 29.25; G31 

88.00 MJ/m3

(2) Gas resistance between boiler connection and measurement point on the gas valve unit

Tab.15

C140

 

 

C140 – 45

C140 – 65

C140 – 90

Gas inlet pressure G20 (H gas)

min–max

Pa

1500 - 3000

1500 - 3000

1500 - 3000

G30/G31 gas inlet pressure (Butane/Propane)

min–max

Pa

3700 - 5000

3700 - 5000

3700 - 5000

G31 gas inlet pressure (Propane)

min–max

Pa

3700 - 5000

3700 - 5000

3700 - 5000

Tab.16 Central heating circuit data

C140

 

 

C140 – 45

C140 – 65

C140 – 90

Water content

 

l

5.2

7.1

10.1

Water operating pressure

 

MPa

0.08

0.08

0.08

Water operating pressure (MOP)

 

MPa

0.4

0.4

0.4

Water temperature

max

°C

110

110

110

Operating temperature range

°C

7–90

7–90

7–90

Pressure drop secondary circuit (ΔT = 20 K)

 

mWC

1.1

1.7

1.6

Maximum permitted temperature difference

(1)

max

°C

40

(1)

40

(1)

40

(1)

(1) with a maximum flow temperature of 80 °C

Tab.17 Electrical data

C140

 

 

C140 – 45

C140 – 65

C140 – 90

Type of power supply (AC)

 

V/Hz

~220/50

Power consumption – full load

 

W

68

92

124

Minimum electrical output for the thermal load 

status

 

W

17

25

24

Power consumption – standby

 

W

5

6

5

Electrical protection rating

 

IP

IPX4D

IPX4D

IPX4D

Fuses

Main

A

10

10

10

Type of protection against electrical shocks

 

 

Class I

Class I

Class I

8  Technical specifications

26

DIEMATIC Evolution - C140

7745361 - v03 - 29112021

Summary of Contents for LN1GBQ41-C140-45

Page 1: ...ADVANCE SUSTAINABLE COMFORT MW 2000880 2 en User Guide control box equipped with a DIEMATIC Evolution Gas fired heating condensing boilers LN1GBQ41 C140 45 LN1GBQ62 C140 65 LN1GBQ86 C140 90...

Page 2: ...sing the product and keep it in a safe place for later reference In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly Our service and customer...

Page 3: ...configuration 14 5 5 Changing the room temperature of a zone 15 5 5 1 Definition of zone 15 5 5 2 Changing the name and symbol of a zone 15 5 5 3 Changing the operating mode of a zone 16 5 5 4 Timer...

Page 4: ...cal data 25 9 Appendix 27 9 1 Product fiche 27 9 2 Product fiche Temperature Controls 27 9 3 Package fiche Boilers 28 9 4 EC Declaration of Conformity 29 Contents 4 DIEMATIC Evolution C140 7745361 v03...

Page 5: ...ore any work switch off the mains supply to the boiler Danger If you smell flue gases 1 Switch off the appliance 2 Open the windows 3 Locate the probable source of the flue gas leak and fix it immedia...

Page 6: ...Depending on the boiler settings the domestic hot water temperature may exceed 65 C Caution Be careful not to directly touch the surface of the viewing window to avoid burns 1 2 Recommendations Dange...

Page 7: ...d be switched to Summer or Frost Protection mode rather than be switched off in order to guarantee the following functions Avoidance of pumps blocking Frost Protection Important Respect the minimum an...

Page 8: ...given in the manuals provided with the appliance Call on a qualified professional to carry out installation and initial commissioning Get your installer to explain your installation to you Have the r...

Page 9: ...nsing gas boilers have the following characteristics Low polluting emissions High efficiency heating Electronic control panel Flue gas discharge by a forced flue or chimney type connection with bi flo...

Page 10: ...he selected tile is highlighted 2 Date and time Name of the screen actual position in the menu 3 Information about the selected tile 4 Error indicator only visible if an error has been found 5 Icon sh...

Page 11: ...ree way valve indicator Display of the system water pressure Chimney sweep mode is enabled forced full load or low load for O2 CO2 measurement Energy saving mode is enabled DHW boost is enabled Timer...

Page 12: ...hey request heat 4 Check the hydraulic pressure in the installation shown on the control panel display Recommended hydraulic pressure between 0 15 and 0 2 MPa 1 5 and 2 0 bar Important In the event of...

Page 13: ...g the user level menus The tiles on the home screen provide quick access for the user to the corresponding menus 1 Use the rotary knob to select the required menu 2 Press the button to confirm the sel...

Page 14: ...n to confirm the selection The Holiday Mode menu opens 3 Use the rotary knob to select Start date holiday 4 Press the button to confirm the selection The current date is displayed as start date of you...

Page 15: ...set at 7 90 C The water temperature of the low temperature heating system should not be higher than 60 C 5 5 Changing the room temperature of a zone 5 5 1 Definition of zone Zone is the term given to...

Page 16: ...e change The room temperature is changed temporarily Holiday The room temperature is reduced during your holiday to save energy Antifrost Protect the boiler and installation from freezing in winter 4...

Page 17: ...ted with each activity The last activity of the day is valid until the first activity of the next day Fig 12 Activities of a timer program AD 3001403 01 0 15 20 25 T 0 00 2 00 4 00 6 00 8 00 10 00 12...

Page 18: ...ratures is shown 5 Use the rotary knob to select an activity 6 Press the button to confirm the selection 7 Set the heating activity temperature 8 Press the button to confirm the selection 5 5 6 Changi...

Page 19: ...lect the timer program you want to modify Schedule 1 Schedule 2 or Schedule 3 7 Press the button to confirm the selection Activities scheduled for Monday are displayed The last scheduled activity of a...

Page 20: ...ot water sensor is installed 1 Select the tile 2 Press the button to confirm the selection 3 Use the rotary knob to select Hot water boost 4 Press the button to confirm the selection 5 Set the duratio...

Page 21: ...he Installation and Service Manual and the relevant section of the Benchmark Service Record completed in order to maintain the warranty Important Taking out a maintenance contract is recommended Cauti...

Page 22: ...e filling draining valve may not be close to the boiler 9 Attach the filling hose to the filling draining valve Tighten the filling hose properly 10 Open the central heating system fill drain valve 11...

Page 23: ...e temperature 3 Wait until the radiators are warm 4 Shut down the boiler 5 Wait approximately 10 minutes until the radiators feel cold 6 Bleed the radiators Work from the lowest to the highest 7 Open...

Page 24: ...fied person in accordance with local and national regulations 7 Troubleshooting 7 1 Error codes The boiler is fitted with an electronic regulation and control unit The heart of the control is a microp...

Page 25: ...t to contact the installer 1 Press the button 2 Press the button to confirm the selection 3 Select System Settings 4 Press the button to confirm the selection 5 Select Installer Details 6 Press the bu...

Page 26: ...0 65 C140 90 Gas inlet pressure G20 H gas min max Pa 1500 3000 1500 3000 1500 3000 G30 G31 gas inlet pressure Butane Propane min max Pa 3700 5000 3700 5000 3700 5000 G31 gas inlet pressure Propane min...

Page 27: ...ce heating energy efficiency class A A 1 Rated heat output Prated or Psup kW 41 62 84 Seasonal space heating energy efficiency 95 94 Annual energy consumption GJ 124 190 Sound power level LWA indoors...

Page 28: ...e products in relation to building size and characteristics Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C Seasonal space heating energy efficiency class of pa...

Page 29: ...ckage with hot water storage tank 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 0 6 0 98 1 00 0 7 1 00 1 00 1 The intermediate values are calculated by linear interpolatio...

Page 30: ...9 Appendix 30 DIEMATIC Evolution C140 7745361 v03 29112021...

Page 31: ...al and technological information contained in these technical instructions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior...

Page 32: ...c aw Serviceline 41 0 8 00 846 846 801 080 881 Infocentrala NEUBERG S A LU DE DIETRICH SERVICE AT DE DIETRICH CN www neuberg lu www dedietrich heating com www dedietrich heiztechnik com 352 0 2 401 40...

Reviews: