1 / INSTALLING YOUR APPLIANCE
Separate the 2 phase wires (L1 and L2) before
connection.
N
L
Green/yellow
Blue
Black or grey
Brown
Neutral
Earth
Phase
N
L1 L2
Blue
Green/yellow
Black-grey
Brown
•Hook-up of 220-240V
~
Warning
If the cable is damaged it must be
replaced by the manufacturer, its after-
sales service or a person with a similar
qualification to prevent danger.
With hook-up of 400 V 2N three phase, verify
that the neutral wire is properly connected.
These hobs must be connected to the mains using a socket in compliance with publication CEI
60083 or an all-pole circuit-breaker device in compliance with the installation rules in force.
When power is first supplied to your hob, or after an extended power cut, an indicator light will
appear on the control panel. This information will disappear after 30 seconds.
Connection
N
L
Green/yellow
Blue
Brown
•Hook-up of 400V 2N
~
-
16A
32A
16A
Separate the wires before connection.
Neutral
Earth
Phase
N1
L1 L2
Blue
Green/yellow
Black-grey
Brown
•Hook-up of 2x230V 2L+2N
~
-
16A
N2
•Hook-up of 400V 3
~
-
16A
Earth
Earth
Neutral
Neutral
Phase
Phase
9964 2283_A_ML.qxp 18/04/2007 10:58 Page 19