Tab.33 Weighting of medium temperature heat pumps
II, package without hot water storage tank
II, package with hot water storage tank
0
1.00
1.00
0.1
0.70
0.63
0.2
0.45
0.30
0.3
0.25
0.15
0.4
0.15
0.06
0.5
0.05
0.02
0.6
0.02
0
≥ 0.7
0
0
(1) The intermediate values are calculated by linear interpolation between the two adjacent values.
(2) Prated is related to the preferential space heater or combination heater.
Tab.34 Package efficiency
AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2
Seasonal space heating energy efficiency of package
%
136
127
131
Tab.35 Package efficiency
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
AWHP 22
TR–2
AWHP 27
TR–2
Seasonal space heating energy efficiency of
package
% 127
127
123
123
116
114
9 Product fiche and package fiche
7684505 - v03 - 14052020
MIT-S
39