DTG 1300-24 Eco / V130
11/09/09 - 300010111-001-B
3.
Description
3 Description
3.1 General description
ECODENS boilers are floor-standing gas-fired condensing boilers.
They are combined with a 130 litre tank to handle domestic hot water
production and central heating using radiators or underfloor heating.
The boilers can operate on natural gas or on butane/propane. They
are factory set for natural gas H.
3.2 Control panel
C000773-B
N Temperature display
The display shows the temperature of the water in the domestic hot water heating outlet when
there is a request for domestic hot water.
O Domestic hot water temperature maintenance
override button
I
With Easymatic remote control:
Pressing the button for 1 second makes it possible to override domestic hot water tank loading
outside the time period programmed in the control unit up to midnight (indicator light O2 flash).
- Light O1 lit : The burner is ignited to reheat the domestic hot water tank.
- Light O2 off : No override or programme running.
- Light O2 lit : Comfort programme activated.
P Safety shutdown light
Indicates an error in the boiler.
Q Reset button
To restart the boiler after safety shutdown.
R Button -
Used only in measurement
V
, installer
K
and sweep
M
mode
.
S
Used only in sweep mode
M
.
T 6-position switch
-
.
: Stop / Anti-freeze / Bleed.
-
: Domestic hot water (Summer).
-
"
: Heating and domestic hot water (Winter).
-
V
: Measurement mode (Key to access the parameters reserved for the installer).
-
K
: Fitter mode (Key to access the parameters reserved for the installer).
-
M
: Sweeping mode (Key to access the parameters reserved for the installer).
U "Heating" on light
The light is on when the heating/domestic hot water reversal valve is in the heating position and the
circulator pump is operating.
V Heating temperature setting
Setting range: 30 °C to 90 °C (Hard spot at 68°C).
W Flame presence light
The light is on when the burner is operating.
X Setting the domestic water temperature
Setting range: 40 °C to 60 °C (Hard spot at 55°C).
Y "Domestic hot water" on light
The light is on when the heating/domestic hot water reversal valve is in the domestic hot water
position and the circulator pump is operating.
Z Pressure indicator
Indicates the pressure in the heating circuit from 0.5 to 2.5 bar.