Easymatic regulator

Flap open

1. Temperature adjustment keys (green keys)

"comfort" temperature

"low" temperature

"domestic hot water" temperature (if a hot
water calorifier is connected)

Note

When one of these keys is pressed:

- the active time program corresponding to the cir-
cuit is displayed in the graphic bar 

- the measured temperature is displayed at the right
of the display.

2. Adjustment keys

or (blue 

keys)

3. Operating mode selection keys (grey keys)

MODE key
To select one of the following operating modes:

AUTO

: operation according to the time pro-

gram 

: forced operation at comfort tempera-

ture until midnight 

: forced operation at reduced tempe-

rature until midnight 

: frost free operation during the pro-

gramed time 

: stop manual heating, production of

domestic hot water only (if a calori-
fier is connected)

Key
To force heating of the domestic hot water tank out-
side the d.h.w. time program (if a calorifier is 
connected).

4. Time and day adjustment key

5. Key to adjust the heating program

PROG

6. Key to adjust the domestic hot water calorifier 

program 

PROG

7. Programing keys

write (in 1/2 hour periods) the “comfort“ 
period or the calorifier heating allowed period
(dark area) 

write (in 1/2 hour periods) the “comfort“ 
period or the calorifier heating not allowed
period (light area)
return to the program graphic bar 

Simultaneously press the 

and 

keys

(STANDARD) for 5 seconds to reinitialize 
programes to factory settings: heating and
d.h.w. from 6 a.m. to 10 p.m.

8. Program display graphic bar (12 a.m. to 12 p.m.)

"Comfort" periods are displayed in black bars at
programed "comfort" times in the graphic bar.

STANDARD

MODE

PROG

PROG

+

-

1

2

3

4

5

6

7

8575N077

8

Summary of Contents for EASYMATIC

Page 1: ...E Control panel Package MA2 Easymatic English 03 14 08 94862243 Instructions for use Electrical connection Start up Please read these instructions and retain for future reference...

Page 2: ...URES 7 5 SETTING THE TIME AND DAY 7 6 PROGRAMING 8 6 1 Factory programing 8 6 2 Program customization 8 7 MESSAGES ALARMS 9 8 STARTUP OR RESTART AFTER A PROLONGED STOP 10 9 ISOMETRIC VIEWS AND LIST OF...

Page 3: ...re by controlling the burner The boiler thermostat must be set to a sufficiently high tempera ture for automatic regulation to operate correctly set ting between mark 8 and 9 The safety thermostat wit...

Page 4: ...uring which the heating is to be cut off D 2 position switch AUTO automatic operation manual forced operation E Test STB push button When pushed and held in safety thermostat tests and cutoff of the h...

Page 5: ...t free operation during the pro gramed time stop manual heating production of domestic hot water only if a calori fier is connected Key To force heating of the domestic hot water tank out side the d h...

Page 6: ...operation the boiler temperature is no longer limited by the regulation the boiler thermostat G is used to regulate the boiler temperature the heating pump and the domestic hot water load pump if ther...

Page 7: ...ressed Tempe Setting range Factory rature setting Domestic hot 40 to 60 C 50 F to 175 F water Adjustment in steps of 55 C 130 F average 1 C 5 F using storage and temperature Tempe Setting range Factor...

Page 8: ...tically copied to other days but it can be modified individually day by day Write dark areas using the key and write light areas using the key 1 2 hour by 1 2 hour Dark areas are applicable to comfort...

Page 9: ...AL L S S1 1 The entire installation automatically changes to Manual mode The burner is controlled by the boiler thermostat G The heating pump runs permanently and the valve is no longer regulated elec...

Page 10: ...e heating program and the d h w program as you wish if you have domestic hot water production see chapter 6 Check that the switch D is in the AUTO position Check that the thermostat G is in the AUTO p...

Page 11: ...ference 8578 4017 MODE 1 2 3 4 5 6 7 0 2 4 6 8 10 12 14 16 18 20 22 24 8578N027 17 3 15 26 27 13 25 2 19 16 20 21 18 22 23 24 29 28 1 4 12 11 9 8 6 5 10 7 14 AD042B DE DIETRICH THERMIQUE S A S au capi...

Page 12: ...DHW SENSOR OPTION PACKAGE FM 45 E EASYMATIC control panel 990 992 995 994 993 991 85757740A EXTERNAL SENSOR 85757741 951 950 952 2 3...

Page 13: ...tic relay board 19 8575 4905 3 pin connector power supply 20 8575 4922 4 pin connector power supply VA CS 21 8575 4924 Pump 3 pin connector A VS 22 8575 4918 2 pin connector boiler sensor 23 8575 4911...

Page 14: ...14...

Page 15: ...15...

Page 16: ...www dedietrich boilers com www dedietrichthermique com...

Page 17: ...ing the supplied accessories 2 CB 4 wood screws inserts 8800N002A 8800N003 Positions to be avoided Installing the outside sensor The outside sensor is installed on the outside wall adja cent to the he...

Page 18: ...is purpose at the back of the boiler control panel The connecting cables may be brought inside the boi ler through the cut outs provided in the boiler back panel which may be used along with purchased...

Page 19: ...13 o 23 22 o o o 15 14 17 16 o o 19 18 o o o 21 20 o SENSOR MAIN SUPPLY 120V 60Hz SAFETY CONTACT 6 7 L N HEATING PUMP 8 9 10 LOAD PUMP 11 12 13 ALARM INDICATOR o 23 22 o 8578N008 S EXT 2 1 C Alim L S...

Page 20: ...ALI 1 2 3 4 5 CS SAFETY CONTACT 6 7 L N HEATING PUMP 8 9 10 LOAD PUMP 11 12 13 o 23 22 o EXTERNAL S EXT o o 15 14 BOILER S CH 17 16 o o DOMESTIC HOT WATER S ECS 19 18 o o ROOM CIRCUIT A S AMB A o 21 2...

Page 21: ...he same operations as for disassembly in the reverse order 5 4 3 2 1 The remote control will be installed adjacent to an internal partition about 1 5 m above the floor in a judi ciously chosen control...

Page 22: ...arefully clip the connector onto the P C B The tabs on the base are different widths so that an inverted connection is impossible Screw the back part of the regulator to the control panel Fix the fron...

Page 23: ...minutes or when you press the MODE key STANDARD MODE PROG PROG 1 2 3 4 5 6 7 0 2 4 6 8 10 12 14 16 18 20 22 24 8575N078 The settings given below are applicable to various functions and the installatio...

Page 24: ...th easymatic control module installed 3 0 to 10 in the heated volume 9 9 Choose Low Night or Night Off mode 0 night stop only with room sensor influence 0 1 1 night low 1 10 0 Frost free ambiance set...

Page 25: ...nto account slightly 3 taken into account medium amount recom mended 10 operation as room thermostat Parameter 9 NIGHT To select one of the following functions for operation at reduced rate if the roo...

Page 26: ...ely hot water from entering the heating circuit after the calorifier heating has been stopped It also prevents overheating in the boiler which could accidentally trip the safety thermostat Parameter 1...

Page 27: ...ECS LOAD PUMP CONTROL RELAY RL PA HEATING PUMP CONTROL RELAY S AMB A ROOM SENSOR S CH BOILER SENSOR S EXT EXTERNAL SENSOR S ECS DOMESTIC HOT WATER SENSOR TELEPHONE RELAY END SWITCH T TRANSFORMER TCH B...

Page 28: ...rio N3E 1A3 CANADA Tel 519 650 0420 Fax 519 650 1709 In USA or South America 1054 North DuPage Avenue Lombard Illinois USA 60148 Tel 630 953 2374 Fax 630 953 2376 Toll Free 1 800 943 6275 www dedietri...

Reviews: