2 / INSTALLING YOUR APPLIANCE
EN
•
•
—
— The power cable (H05 RR-F, H05 RN-F or H05 VV-F) must be of sufficient length to be
connected to the build-in oven while it sits on the floor in front of the cabinet.
To do this the appliance must be disconnected from the electrical network:
—
— Open the inspection flap located at the lower right of the back cover by unscrewing the two
screws, then pivot the inspection flap.
—
— Strip 12 mm along each wire of the new power cable.
—
— Carefully twist the strands together.
—
— Loosen the screws from the terminal board and remove the power cord to be replaced.
—
— Insert the power cable through the side of the cover into the cable clip located to the right of
the terminal board.
—
— All the strands of the electrical wires must be secured tightly under the screws.
— The phase wire on the L terminal.
— The green-yellow coloured earth wire should be connected to the terminal
.
—
— The neutral wire (blue) on the N terminal.
---- Connect the wires according to the table on page 7.
—
— Screw down tightly the screws on the terminal board and check the connection by pulling on each
wire.
—
— Attach the cable with the cable clip located to the right of the terminal board.
—
— Close the inspection flap using the two screws.
Warning
We cannot be held responsible for any accident resulting from inexistent, defective or
incorrect earthing.
If the electrical installation in your residence requires any changes in order to hook up your
appliance, contact a professional electrician.
If the oven malfunctions in any way, unplug the appliance or remove the fuse corresponding
to the sector where the oven is hooked up.
The oven is sold without a cable.
1st CONNECTION OR CHANGE OF THE POWER CABLE