18
•
2
INSTALLATION
ELECTRICAL CONNECTION
During installation and maintenance ope-
rations, the appliance must be disconnec-
ted from the mains; fuses must be
isolated or removed.
The electrical connections should be
made before the appliance is installed in
its housing.
Check that:
- the electrical installation is sufficiently
rated,
- the supply wires are in good condition,
- the diameter of the wires complies with
the installation requirements.
This appliance is supplied fitted with a
3-core (phase, neutral and earth)
0.75mm
2
H 05 VVF cable. It must be
connected to a 220-240V single phase
mains network via an IEC 60083 socket
which must remain accessible after ins-
tallation, in accordance with the installa-
tion rules.
The fuse in your installation must be 10
or 16A. If the mains cable is damaged,
call after-sales service and so avoid any
danger.
If the electrical installation in your home
requires any changes in order to connect
your appliance, contact a professional
electrician.
If the hood malfunctions in any way, un-
plug it or remove the fuse for the circuit
concerned.
The installation must comply with current
regulations for the ventilation of rooms. In
particular, air must not be evacuated into
a duct used to evacuate fumes from ap-
pliances using gas or other fuels. Disused
ducts may only be brought into service, if
approved by a competent specialist. The
evacuation line, whatever its type, must
not emerge in a loft space
.
2.1 - USE IN EVACUATION MODE
You have a duct that leads outside.
Your hood may be connected to it via an
evacuation duct (minimum 125mm dia.,
made of enamelled, aluminium hose or
other non-flammable material). If your
duct is less than 125mm in diameter, you
must change to recycling mode.
2.2 - USE IN RECYCLING MODE
You do not have a duct leading to the out-
side.
All our appliances can operate in recy-
cling mode.
In such a case, purchase a recycling kit
comprising a set of active carbon filters
and a deflector.
Energy saving advice
To obtain the best performance from your
appliance, limit the number of bends and
length of the duct as much as possible.
2
.3 - FITTING THE HOOD
The minimum distance between the coo-
king surface (2.3) and the lowest part of
the hood is 65cm. If the instructions for a
hob installed below the hood specify a
distance greater than 65 cm, then that
distance must be applied.
- Draw a horizontal line (A) at least 65cm
above the cooking surface.
- Draw a vertical line (B) on the wall, cen-
tred on the cooking surface running
from the ceiling to the previous horizon-
tal line (A).
- Place the drilling guide (C) against the
wall.
- Drill the two holes. Install the plugs.
For hollow walls, use suitable plugs and
Summary of Contents for DHB7931X
Page 2: ... 1 I 274 mm 900 mm 65 mm 500 mm 331 mm Min 650 Max 1002 mm Min 750 Max 1102 mm 602 mm ...
Page 3: ... 1 1 1 1 x G 1 x N 1 2 II 1 x C 1 x F 1 x J 1 x L 5 x D E 1 x H 1x K 2 x M ...
Page 4: ... 2 125 150 125 150 B A C D E 2 1 2 2 2 3 III ...
Page 5: ...K 2 2 3 1 IV ...
Page 6: ... 2 2 4 V F H I G H I K J L M M ...
Page 7: ... 4 3 4 3 VI ...
Page 92: ...CZ5703114_00 03 17 ...