C 330 ECO
280
350
430
500
570
650
Sound power level, indoors
L
WA
dB
69
69
73
-
-
-
Emissions of nitrogen oxides
NO
X
mg/kWh 46
50
49
-
-
-
(1) Low temperature means 30 °C for condensing boilers, 37 °C for low temperature boilers and 50 °C (at heater inlet) for other heating
appliances.
(2) High temperature operation means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
See
Refer to the back cover for contact details.
3.2.2
C 630 ECO technical data
Tab.9
General
C 630 ECO
560
700
860
1000
1140
1300
Number of sections
2x5
2x6
2x7
2x8
2x9
2x10
Nominal output (Pn)
(80/60 °C)
min
max
kW
69
522
87
654
123
790
122
922
148
1060
158
1202
Nominal output (Pn)
(50/30 °C)
max
kW
558
700
850
994
1148
1303
Nominal load (Qnh)
(Hi)
min
max
kW
72
532
91
666
128
804
127
938
153
1078
162
1220
Nominal load (Qnh)
(Hs)
min
max
kW
80
590
101
738
142
890
141
1040
170
1196
180
1354
Full load central heating efficiency
(Hi) (80/60 °C) (92/42/EEC)
%
98.0
98.1
98.2
98.3
98.4
98.5
Full load central heating efficiency
(Hi) (50/30 °C) (EN15502)
%
104.8
105.2
105.6
106.0
106.4
106.8
Central heating efficiency under
part load (Hi)
(Return temperature 60 °C)
%
94.7
95.3
95.8
96.3
96.8
97.3
Annual efficiency G20 (DIN 4702,
Part 8)
%
109.6
109.5
109.4
109.3
109.2
109.1
Part load central heating efficiency
(92/42 EEC)
(Return temperature 30 °C)
%
109.2
109.0
108.8
108.6
108.3
108.1
(1)
Factory setting.
Tab.10 Gas and flue gas data
C 630 ECO
560
700
860
1000
1140
1300
Gas inlet pressure G20 (H gas)
min
max
mbar
17
30
17
30
17
100
17
100
17
100
17
30
Gas inlet pressure G25 (L gas)
min
max
mbar
17
30
17
30
17
100
17
100
17
100
17
30
Gas consumption G20 (H gas)
min
max
m
3
/h
7.6
56.2
9.6
70.4
13.5
85.0
13.4
99.2
16.2
114.0
17.2
129.2
Gas consumption G25 (L gas)
min
max
m
3
/h
8.9
65.4
11.2
82.0
15.8
99.0
15.6
115.4
18.8
132.6
19.9
150.2
NOx annual emissions G20
EN15502
O
2
= 0%
ppm
28.9
31.7
30.6
28.9
30.6
27
NOx annual emissions G20
EN15502
H
i
mg/kWh 51.0
56.0
54.0
51.0
54.0
47.6
NOx annual emissions G20
EN15502
H
s
mg/kWh 45.9
50.5
48.6
45.9
48.6
42.9
Flue gas mass flow rate
min
max
kg/h
182
896
228
1120
276
1352
320
1578
366
1814
410
2052
3 Technical specifications
14