QM
1 / 2
IT2673A
TI
Technical information
Heat pumps
Outdoor units AWHP... - All powers
Option Electrical tracing kit (Heating cord)
Package EH113
01.45.91.56.02 – G.CHAMPION /J. SCHALCK
N° IT2673A
-en
20/06/2018
EN
SUSTAINABLE COMFORT®
1. Purpose
On the field, we noticed that the installation of the heating cord (EH113) does not comply with our recommendations
and the rules of the art. These non-compliances led to fire starts.
Therefore, and for safety reasons, we ask you to check the whole installed product park, during the mandatory
annual maintenance.
2. Accessories concerned
100012532 - Condensate container for wall bracket (Package EH111)
100012534 - Electrical tracing kit (Package EH113)
3. Main checkings
3.1
Thoroughly inspect the condition of the cord:
Check if the heating cord is not damaged (bare or cut), if it has not been damaged by rodents,...
- Only qualified professionals are authorised to work on the appliance and the
installation.
- Before any intervention, ensure compliance with safety standards (including the
grounding of metal pipes in accordance with the professional standards).
- Any manipulation of the heating cord must be done with the power OFF !
- Follow the instructions hereafter to avoid any risk of overheating and fire !
- It is strictly forbidden to modify the structure of the electric heating cord !
Remove the cord if it is damaged !