Technical changes reserved - 2022
3.
Safety Device:
3.1
Don’t
connect the device to the circuit during maintenance. Disconnect it properly and carefully from the
circuit and make sure it
won’t
get turned on unintentionally.
3.2
There cannot be any water pressure in the device during maintenance work.
3.3
Always wear gloves while you are doing maintenance work while the reactor case is open.
4.
Power Connection:
4.1
Power supply 230 Volt, 50 Hz.
4.2
Install a FI-safety switch 0,03 A into the power connection.
4.3
The device must be connected, electrically, through the filter pump and can only be operated with a running pump. (see circuit
diagram)
The ground wire (PE) has to be connected in the control box and to the reactor case. Make sure that in the filter room, all metal
parts must be included in the equipotential bonding conductor.
5.
Circuit Diagramm:
6.
Mode of Operation:
6.1
The device can be switched on or off with the power switch (O/I). The red indicator lamp shows that there is power available.
6.2
Switch the power switch to I. As soon as there is power, the power switch will turn red, and the UV-C lamp will start.
6.3
The UV-
C lamp is ready to operate when the indicator light is green. If the green operating lamp doesn’t
6.4
light up or if it switches off, either the controller or the lamp is damaged. Disinfection is not taking place!
6.5
The flow rate in the device should not exceed the indicated maximum values; otherwise, the time in the reactor will be too short.
This might lead to insufficient effectiveness. In the bypass-system bigger bathing water pumps can be used.
6.6
It is important to find out the UV-
lamp’s exact
lifetime either by using the timer or by calculating it. After
6.7
9000 hours the lamp won’t be effective anymore and has to be changed.
6.8
In order for the device to remain effective, make sure that the quartz tube is always clean.