DeCrane Aerospace Audio International
MAP-9101-10x-x Installation Manual
Document # 540372, Rev IR, 12/2008
Page 8 of 29
Only model MAP-9101-101-x’s can be used to connect a
USB mouse connection for map control. Either USB port
will accept the mouse connection.
3.0
Installation
3.1
Prior to Installation
3.1.1 During the design and layout of the aircraft cabin, careful
consideration of the location of the MAP-9101-10x-x is necessary.
Some of the items to be considered include:
•
Space
•
Proximity to other devices (i.e. source equipment)
•
Available power supply
•
Length of cable runs
•
Environmental conditions (temperature, humidity, etc.)
•
Location of other aircraft systems (i.e. oxygen delivery)
•
Access for service repair (if applicable)
3.1.2 The MAP-9101-10x-x shall be installed to conform to the standards
designated by the customer, installing agency, and existing
conditions as to the unit location and type of installation.
3.1.3 Mounting provisions are provided via four (4) 0.187-inch diameter
mounting holes – two (2) on each side of unit on provided mounting
flanges. Refer to Section 7.0, Reference Drawings, for mounting
hole diameters and configuration.
3.1.4 The unit is capable of installation/mounting in any orientation
whether horizontal, vertical, inverted, or at an angle.
3.1.5 An internal fan exhausts heat from the unit. Proper ventilation must
be allowed for when specifying the installation location. The
closeout area of the monitor shall have a clearance of 2 inches
(5.08 cm) minimum for the air inlet and exit areas. The closeout
area of the monitor case shall not block the air inlet or exhaust
openings of the monitor case. The fan will only run when the unit is
turned on.
3.1.6 Installation requires 2-inch spacing from other equipment, modules,
and structures except the mounting surface for which the unit
should be in direct contact.