DeCrane Aerospace Audio International, Inc.
LCD-9121-101-x Installation Manual
Document # 540365, Rev IR, 03/2008
Page 6 of 18
3.1.8 Unit chassis ground provided by 8-32 ground lug, see Section 6.0.
Bonding between ground lug and airframe installation to be <1
resistance using <50 impedance cable. No surface prep is
required due to conductive chassis finish.
3.1.9 The monitor should be located as close to the source equipment as
possible in order to reduce the possibility of noise introduced into
the video. Refer to Section 6.0 for unit dimensions.
3.1.10 The LCD-9121-101-x is configured using the external menu
selection switch, SP-LCD6. The switch utilizes a D-Subminiature
connector. This connector mates with the D-Subminiature
connector on the LCD-9121-101-1 model monitor.
3.2 Unpacking and Inspection
3.2.1 Carefully open the packaging and remove the LCD-9121-101-x.
Verify that all components have been included in the package per
the packing list. Inspect the unit for damage. Retain the packing
materials and packing list.
3.2.2 If damage has occurred during shipping, a claim should be filed
with DeCrane Aerospace Audio International WITHIN 24 hours and
a
Return Request Authorization Number
shall be obtained from
DAAI by contacting the Repair Department at 501.801.8101.
Repackage the unit in its original packaging materials and return it
to DAAI following instructions given by the DAAI representative.
Refer to the front cover of this manual for address. If no return is
necessary, retain the packing list and the packing materials for
storage.
3.3
Cautions and Warnings
3.3.1 It is important to do a pin-to-pin power and ground check on all
connectors. Ensure that power and ground are applied only where
specified. Damage to the unit may result if power or ground is
applied to the wrong points.
3.3.2
3.3.3
DO NOT
connect or disconnect the monitor while power is applied.
3.3.4
DO NOT
remove any factory-installed screws. Damage to the unit
may result and void any warranties.
3.3.4
DO NOT
expose to moisture.