background image

 

Instruction manual 

 

Automatic phone announcement unit Telealarm GSM 

 

Page 9 

 

 

8 Display- Indication 

 
 
 
 

 

 
 
After the switching-on of the device, following information appears on the display: 
 

 

Left above

 => Status of the device 

 

Possible status indications (S followed from 3 figures): 
 
S500 

SIM Card missing 

S501 

SIM Card is void 

S502 

No GSM network available 

S503 

PIN Number is wrong 

S504 

GSM network available, but not logged in 

S505 

Search for an available GSM net is working 

S510 

logged in GSM net, home net 

S511 

logged in GSM net, roaming 

 
 

 

Right above

 => Alarm status 

 

Possible alarm status indications: 
 
A100 

Alarm analysis is deactivated 

A101 

Alarm analysis is activated, no alarm have been recognised 

A102 

Alarm recognised, the delay time runs 

A103 

Delay time elapsed, call is made 

A104 

The call has been made 

 
 

 

Centre 

=> The name or the number of the network operator 

 
 

 

Left below 

=> The GSM field strength with 0 till 5 bars 

Alarm status 

Device status 

Network operator 

GSM  field intensity 

Battery indication 

Summary of Contents for Telealarm GSM

Page 1: ...Instruction manual Automatic phone announcement unit Telealarm GSM requires 2G network GSM Manufacturer deconta GmbH Im Geer 20 D 46419 Isselburg Name Type No Telealarm GSM Type 531 Serial number...

Page 2: ...3 Transport 5 31 Delivery 5 3 2 Transport 5 4 Scope of delivery 5 5 Technical discription 6 6 Technical data 7 6 1 Technical data 7 6 2 Equipment 7 7 Intial operation 8 7 1 Important advices 8 7 2 Ins...

Page 3: ...products guarantee Stability Long life and servicability on site Mechanics with kick Pleasing design The copyright of this instruction manual remains with deconta This manual is intended for assembly...

Page 4: ...ure the safety during the operation of the device you have to respect without fail the following Do not place in an explosive area Necessary repairs maintenance and cleaning in particular in the field...

Page 5: ...or another supplier Please note the possible damages additionally on the way bill During the transport you have to handle with care of course in order to avoid damages due to faulty handling or imprud...

Page 6: ...he use you only need a SIM Card and current An integrated battery which is automatically charged via mains voltage guarantees a safe use also during outages Together with the negative pressure monitor...

Page 7: ...ength 236 mm Width 186 mm Height 335 mm Weight 4 86 kg Current 230 V 16 A Battery 12 V 1 2 Ah 6 2 Equipment Powder coated casing Big display with backlight Keyboard anti vandalism Contact potential fr...

Page 8: ...ocks Do not operate the automatic announcement unit in the contaminated area 7 2 Insertion of the SIM Card If the SIM Card is protected through a PIN Number you have to memorise this number before ins...

Page 9: ...le but not logged in S505 Search for an available GSM net is working S510 logged in GSM net home net S511 logged in GSM net roaming Right above Alarm status Possible alarm status indications A100 Alar...

Page 10: ...same way on the keyboard Press the key C appears on the display Enter the Code for the suitable setting see following code chart Press the key The actual adjusted value appears Enter a new value Conf...

Page 11: ...mber of the SIM Card 4 digits 30 Interpretation of the set up of the potential free contact Alert entry 0 Alert by opened contact for aircontrol 1 and 2 for aircontrol plus for aircontrol online for a...

Page 12: ...GmbH Im Geer 20 D 46419 Isselburg Product Automatic play out message device Type 531 The design of the unit corresponds EC Machine directive 93 68 EWG with the following regulations EC low voltage dir...

Reviews: