Original instruction manual 

 

Negative Pressure Units 

 

green dec

 

 

G 700 

 
 

 

 

 
Manufacturer: 

 

deconta  GmbH 

    Im 

Geer 

20, 

46419 

Isselburg 

 
Designation / Type No.: 

Negative pressure unit 

green dec G 700 

 

Typ 704

 

 
Serial No.: 

 

 

................. 

 

 

Summary of Contents for green dec G 700

Page 1: ...Original instruction manual Negative Pressure Units green dec G 700 Manufacturer deconta GmbH Im Geer 20 46419 Isselburg Designation Type No Negative pressure unit green dec G 700 Typ 704 Serial No...

Page 2: ...on 10 5 2 Control SRE connect 10 6 Assembly instruction 11 7 Initial operation 12 7 1 Preparations 12 7 2 Control SRE connect 13 7 2 1 Create your user account 14 7 2 2 Add the device to your user acc...

Page 3: ...ncluding removal and replacement of the filters may only be carried out by authorized persons wearing suitable protective clothing The device must be completely disconnected from the power supply duri...

Page 4: ...vironment For these reasons contaminated areas are separated from the asbestos free areas and kept under dynamic negative pressure by means of negative pressure units An integrated filter system reduc...

Page 5: ...a qualified electrician CAUTION Damage due to unsuitable mains voltage The device can be damaged if it is connected to an unsuitable mains voltage Check whether the voltage indicated on the rating pla...

Page 6: ...only Attach the transport lids on the suction side and if used filters are installed also cover them 3 Delivery contents Included in the delivery contents of a negative pressure unit independent of w...

Page 7: ...n 35 A Motor power 4 x 5 7 kW Filter system 3 stage Pre filter EU4 dimensions 610 x 610 x 47 Bag filter F5 dimensions 592 x 592 x 600 HEPA filter dimensions 610 x 610 x 292 4 2 Connections dimensions...

Page 8: ...Pre filter Quality class acc to DIN 24185 EN 779 G4 EU4 Frame Cardboard frame 47 mm wide Filter medium Synthetic Degree of separation Am 90 Nominal volume flow 5400m h m Nominal flow velocity at nomi...

Page 9: ...nal pressure drop 250 Pa Temperature humidity 55 C 100 RH relative humidity Filter dimensions in m 5 1 m Filter dimensions in mm 592 x 592 x 600 mm 4 3 3 HEPA filter Frame Plastic Filter medium Micro...

Page 10: ...t IoT Internet of Things Devices with SRE connect control can be remotely controlled and monitored with any internet enabled computer mobile phone or tablet For power regulation the negative pressure...

Page 11: ...nd is intended for immediate commissioning In case of visible damage do not operate the unit Please contact deconta GmbH immediately Place the container on the containment area Seal the container with...

Page 12: ...it to the negative pressure connection with the PE hose 8 x 1 Determine the measuring point in the clean area adjoining rooms and connect to the atmosphere connection with PE hose 8 x 1 Turn on the ma...

Page 13: ...Ireland Israel Italy Japan Jersey Kazakhstan Kuwait Kyrgyzstan Laos Latvia Liechtenstein Lithuania Luxembourg Macau Macedonia Malaysia Malta Martinique Moldova Mongolia Montenegro Nepal Netherlands N...

Page 14: ...ess the tab Sign Up and enter your e mail address and desired password The password must be at least 8 characters long and must meet 3 of the following 4 criteria At least 1 number At least 1 capital...

Page 15: ...Unit green dec G 700 Version 3 Page 15 7 2 2 Add the device to your user account Turn on your device Press the button Menu Press the button Service Press the button deconta connect The page with a QR...

Page 16: ...en dec G 700 Version 3 Page 16 Log in with your e mail address and with your password on the connect page Press the menu icon and then choose Devices Press the button SCAN QR CODE our recommendation o...

Page 17: ...he button SUBMIT changes to green In order to add the device press this button Now the device is registered in your user account Alternative registration via the button SOFTWARE KEY Enter the key that...

Page 18: ...e central control station supplied by customer The control can be used in 2 different operating modes 7 2 3 Manual mode In manual operation mode the fan power is specified with the and buttons The dis...

Page 19: ...mode settings The following parameters can be set minimum negative pressure in day mode minimum negative pressure in night mode minimum volume flow in m h maximum negative pressure The automatic mode...

Page 20: ...Standby mode A negative pressure unit with SRE connect can be operated as a standby device replacement device If this function is activated the device switches itself automatically on if a predefined...

Page 21: ...actual current in A Middle down side displays the actual power in kW Right side displays the watt hours and below the total consumption in KWh 7 2 8 Dust sensor A filter sensor monitors the particle...

Page 22: ...reen dec G 700 Version 3 Page 22 7 2 9 Service deconta connect Allocate the device to a connect account see point 7 2 2 Maintenance Settings in this menu can only be made by qualified deconta service...

Page 23: ...count are displayed there in the set time zone default UTC 0 coordinated world time By pressing the yellow button Reset factory settings the red button Reset factory settings is activated By pressing...

Page 24: ...Instruction Manual Negative Pressure Unit green dec G 700 Version 3 Page 24 7 2 10 Software packages Display of the booked options and the expiration date of the licenses...

Page 25: ...tion 7 2 12 Alarms Alarms are visually displayed via a flashing icon on the main screen At the same time an acoustic signal sounds There are 3 different icons green checkmark there is no alarm message...

Page 26: ...Negative pressure The set nominal value for the minimum negative pressure could not be reached Volume flow The set nominal value for the minimum volume flow could not be reached High dust load Messag...

Page 27: ...ensors Please note when the sensors are switched off the particle concentration in the exhaust air is not monitored 7 2 13 Turn off the device To switch off the device press on the red button OFF In o...

Page 28: ...nting or negative pressurisation must be serviced as required at least once a year and checked by a qualified technician The test result shall be presented on request 8 1 Information on filter change...

Page 29: ...Contaminated filters must only be changed while observing all relevant safety precautions Filter change only when the unit is switched off Use only approved filters Do not use residual fiber bonding a...

Page 30: ...sure Unit green dec G 700 Version 3 Page 30 Change of bag filters Remove the pre filters Open the locks of the bag filters Remove bag filters Insert new bag filters the bags should be vertical Close t...

Page 31: ...for pre and bag filters by loosening and removing the screws Remove the clamping bars of HEPA filters Remove and dispose HEPA filters Check and clean the sealing surfaces on the device Insert new filt...

Page 32: ...egative pressure too low Pre intermediate or HEPA filter contaminated Filter change as described in 8 2 Unit does not work Power source out of order Get the power source checked and repaired by a qual...

Page 33: ...performance A1 A2 A3 A4 A5 B1 B2 B3 B4 B5 C1 D1 C2 D2 C3 D3 C4 D4 C5 D5 30 67 65 64 61 60 67 65 63 61 60 64 63 61 60 60 40 68 67 64 63 63 69 65 64 62 61 67 67 66 65 63 50 69 68 67 66 64 71 70 68 66 6...

Page 34: ...id crushing or parts of the human body EN 50274 2002 AC 2009 Low voltage switchgear and controlgear assemblies Protection against electric shock Protection against accidental direct contact with dange...