background image

 

Instruction manual 

 

Water treatment boiler system C 130 L 

 

 

 

 

 

page 5 

 

3 Volume of delivery 

 
If no other agreements have been made, the scope of delivery of the water management 
unit consists of: 
 

 Water Management System 

 Filter 

 Instruction manual 

 
 

Return delivery after termination of rental period 

 
We have to insist on following conditions for the return delivery in order to protect our 
clients and in accordance with the rules for hazardous materials transportation: 
 

  As listed above 

  Well cleaned (ready for use) 

  Without binder remains 

 Without 

damages 

 Without 

filter 

 
 

4 Technical description 

 

4.1 Intended use 

 
During asbestos sanitation works within closed rooms, you have to exclude that the 
asbestos fibres leave the sanitation area uncontrolled and endanger the human health 
and the environment. For this reason, personnel must leave the sanitation area through a 
lock system and take a shower while leaving. 
 
The deconta water treatment heats up the shower water and takes over the filtering of 
the contaminated sewage water. 
 

4.2 Unit description 

 
Water filling can be managed manually through a filling opening (with bucket) or 
automatically with a permanently connected clean hose. Inside the powder coated device 
is the water tank (Volume 130 Litres),with an immersion heater, 2 pumps (shower and 
sewage water pump) as well as a 3 stage waste water filtration unit are installed within 
the device The filling-in depending on the temperature (step by step), water temperature 
selected freely up to + 80° C.

 

 

Summary of Contents for C 130 L

Page 1: ...Instruction manual Water treatment boiler system C 130 L Manufacturer deconta GmbH Im Geer 20 D 46419 Isselburg Description Water treatment system C 130 L Type 546 547 Serial No...

Page 2: ...description 5 4 1 Intended use 5 4 2 Unit description 5 5 Technical data 6 6 Initial operation 7 6 1 Version with one Sewage pump 7 6 2 Version with two sewage pumps for 2nd shower 9 7 Maintenance an...

Page 3: ...ent of non observance deconta assumes no liability To ensure safety during operation of the unit the following must be strictly observed Do not use in potentially explosive areas Necessary repairs and...

Page 4: ...it cannot be guaranteed In winter and at risk of frost the whole unit Pump filter housing and tank needs to be emptied before transport Attention Transport of unit also relocation only when empty 2 3...

Page 5: ...sed rooms you have to exclude that the asbestos fibres leave the sanitation area uncontrolled and endanger the human health and the environment For this reason personnel must leave the sanitation area...

Page 6: ...ume Service Water 130 Litre Tank filling automatic or manual via filling opening Heat output 3000 W Filter stages 3 Filter sizes 10 Power outlet 230 V Power consumption 13 A Water connections System G...

Page 7: ...the shaft The strong initial rotational resistance of the new pumps will come loose after running Safety instructions During works on the device always disconnect the plug Operate the device only wit...

Page 8: ...ter housing of 220 filter with water Tighten cap nut of filter housing hand tight Connect to power Set temperature of thermostat red pointer to max 40 C The temperature can be checked on the temperatu...

Page 9: ...esent o Connect Warm water Shower 2 with shower roof o Connect Cold water Shower 2 with cold water connection of shower roof if present o Connect Sewage IN 1 with shower floor o Connect Sewage IN 2 wi...

Page 10: ...tch automatic operation to Pump 1 if only one sewage pump is in use or Pump 1 2 if both pumps are in use the unit is now ready to operate In operating status condensation water may leak out of overflo...

Page 11: ...t Control of fine filter via manometer 7 2 Filter change The Manometer controls the fine filter We recommend a filter change at approx 3bar Attention Change Filter only when device is switched off Dem...

Page 12: ...rst use Repairs and maintenance must only be executed under the observance of all relevant safety measures All the filters mentioned have to be disposed of according to the respective legal terms 7 3...

Page 13: ...Instruction manual Water treatment boiler system C 130 L page 13 8 Circuit diagram 8 1 Version with one sewage pump...

Page 14: ...Instruction manual Water treatment boiler system C 130 L page 14 8 2 Version with two sewage pumps...

Page 15: ...Im Geer 20 D 46419 Isselburg Product Water management C 130 L Type 546 547 The design of the unit complies with EU Machine directive 2006 42 EG the following directives EU Low voltage directive 2006 9...

Reviews: