background image

 

Instruction manual 

 

AS 300 CG 

 

Seite 5 

 

3 Transport 

3.1 Delivery 

 
If no other agreements have been made, the unit is packed safely and will be delivered 
ex work. Transport damages have to be documented immediately upon delivery by the 
carrier or another supplier. Please note the possible damages additionally on the way bill.  
The Transport is to be proceeded with care to avoid damages by improper handling or 
carelessness.  
 

3.2 Transport

 

 
It is important to avoid exposure to violent shocks, otherwise the function and safety of 
the unit cannot be guaranteed. In winter and at risk of frost, the whole unit (waste water 
pump and filter housing) needs to be emptied before transport.  
 

3.3 Storage 

 
In order to avoid damages, the installation has to be kept in a dry area with no access for 
unauthorized persons. 
 
Because of risk of frost in winter it is important to observe the following: 

  Drain the water pipes and empty filter housings  

  Drain the water pump through the drain screw 

  Place the water treatment system in a frost-protected area 

 
 
 

 

 
 
 

Ventilation connection

 

Drain screw

 

Summary of Contents for AS 300 CG

Page 1: ...Instruction manual Waste water filtration unit AS 300 CG Manufacturer deconta GmbH Im Geer 20 D 46419 Isselburg Descriptioin Type No AS 300 CG Typ 539...

Page 2: ...livery 6 5 Technical description 6 5 1 Unit description 6 5 2 Effectiveness of waste water filtration 7 6 Technical data 8 6 1 Connections Dimensions Weights 8 6 2 Waste water pump 8 6 3 Filter system...

Page 3: ...antee Stability long life and serviceability on site Mechanics with kick Pleasing design The copyright of this instruction manual remains with deconta This manual is intended for assembly operation an...

Page 4: ...no liability 2 2 Operation In order to ensure the safety during the operation of the device the following must be observed Do not use in hazardous areas Necessary repairs maintenance and cleaning in p...

Page 5: ...rt It is important to avoid exposure to violent shocks otherwise the function and safety of the unit cannot be guaranteed In winter and at risk of frost the whole unit waste water pump and filter hous...

Page 6: ...n 5 1 Unit description The waste water contaminated with asbestos fibres is cleaned via a 4 stage filtering unit composed of a coarse pre filter bag filter 220 rinsing filter 220 fine filter 50 and fi...

Page 7: ...15 16 17 0 10 20 30 40 50 60 70 80 90 100 0 77 0 97 1 22 1 54 1 93 2 44 3 07 3 87 4 87 6 14 7 74 9 75 12 3 15 5 19 5 24 6 30 9 Measuring point Diameter Effectiveness 1 0 77 84 3 2 0 97 90 4 3 1 22 93...

Page 8: ...x 462 x 775 mm Weight ca 56 kg 6 2 Waste water pump Self priming and safe to run dry Voltage 230V 50Hz Capacity 0 45 kw Flow capacity max 30 l min max medium temperature 90 C Fuse type IP44 6 3 Filte...

Page 9: ...side and move the shaft The strong initial rotational resistance of the new pumps will come loose after running Fill waste water pump fully through vent connection Tighten the cap nut of the filter h...

Page 10: ...tic On Off switch function is available Before the initial operation of the waste water pump or after a long period of stagnation check that the shaft rotates freely when turned by hand To this put a...

Page 11: ...lish power supply 230V 50Hz Schuko plug Switch on unit Position AUTO at selector switch The proximity switch at the waste water hose recognizes if there is water in the hose and switches the Waste wat...

Page 12: ...oarse pre filter may be removed cleaned and reused The Manometer controls the fine filter We recommend a filter change at approx 3bar Attention Change Filter only when device is switched off Demount d...

Page 13: ...attention to correct fit and cleanliness of the seal ring Tighten cap nut by hand The suction hoses pumps filter housings and filter are contaminated after the first use Repairs and maintenance must...

Page 14: ...Instruction manual AS 300 CG Seite 14 9 Circuit diagram...

Page 15: ...46419 Isselburg Product Waste water filtration unit Typ 539 The design of the unit complies with EU Machine directive 2006 42 EG the following directives EU Low voltage directive 2006 95 EG Applied h...